Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Instructions - Honeywell NORTH EVAMASQUE ABEK15 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
Do not use the filtering escape device if the protective shell or adhesive tape is damaged or the seal
is broken. Refer to maintenance instructions.
The seal of the filtering escape device is also affected by size and facial structure of the user, e.g.
beard hair, deep scars, sideburns, etc.
Do not remove the filtering escape device before leaving the contaminated area.
The filtering escape device provides limited protection against low boiling point solvents
The filtering escape device provides limited protection against high concentrations of hazardous
substances (filtration duration will be reduced, or filter can become inefficient at very high
concentrations).
Do not use filtering escape device in tanks or confined spaces.
The filtering escape device is designed for use in escape situations. Please consult the supplier if
you have any doubt as to whether the respirator is suitable for the situation in which you intend to
use it.
Leave the area as soon as the vapour or odour of the contaminants becomes perceptible. The filter
is "saturated". It has to be changed.
In normal use, breathe slowly and regularly (inexperienced users may have difficulty breathing).
When removing the filtering escape device, take all necessary precautions to avoid inhaling the
dust or contaminant retained on the external surface of the filtering escape device.
The EVAMASQUE half mask must only be used with the HONEYWELL filter ABEK reference
1728571.
Disposal
Respiratory filters should be disposed of as hazardous waste corresponding to your local hazardous waste
disposal regulations.
Technical data
Dimensions (including packing materials):
Weight (including packing materials):
Maximum service life of the device:

MAINTENANCE INSTRUCTIONS

Maintenance may only be carried out by Honeywell authorized and trained personnel or organizations. The
filtering escape device must undergo maintenance as described below every four years, or if opened by mistake,
or opened for an escape.
APPROVALS
Product complies with the European Parliament and Council Regulation 2016/425/EU for Personal Protective
Equipment and subsequent amendments.
The EU type-examination as per Module B of PPE Regulation is carried out by the notified body number 0158:
DEKRA EXAM GmbH
Dinnendahlstraße 9
44809 Bochum – GERMANY
The production process based on quality assurance of the conformity to type set out in Module D of PPE
Regulation is under surveillance of the notified body number 0082:
APAVE SUDEUROPE SAS - CS60193
13322 MARSEILLE Cedex 16 - FRANCE
The complete declaration of conformity can be found at: https://doc.honeywellsafety.com/
15.4 x 10.5 x 8 cm
365 g
12 years (2 filter changes if filtering device is never used).
EN-2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis