• The receiver PIN can be modified via the CardinTX_SW software.
• Telephone numbers may have only one entry in the address book and all duplicates will be ignored.
• The modem will ignore all incoming calls without a declared telephone number.
• When inactive the system will periodically check the status of the modem. The control cycle will be repeated
round about every 60 seconds
• Should the CAR code become corrupt and you are not able to access the receiver through the CardinTX_
SW software and you can try and reset it via SMS. If you are unsuccessful you will have to cancel the
memory content and reset the code by resetting the receiver parameters to the factory defaults.
• The USB connection requires a "mini-B" cable connection.
*
SIM VODAFONE-CARDIN
The receiver can be purchased already configured for the installation and equipped with a VODAFONE M2M
SIM telephone card which only for data use with the CARDIN gateway service. This configuration requires
the receiver to connect to the gateway only through a VODAFONE SIM wake-up request.
The number of permitted wake-ups and the amount of data traffic available for the connections is limited
to a monthly amount.
MENU: SIGNAL
(only when the modem is ready)
When the 2G/3G modem is ready [G] or [3G] will appear on the display and you can check the level and
quality of the available signal cover.
The information, updated every 500 ms, is represented by two numbers: the first one shows the signal
intensity detected by the modem and the second number shows the signal quality. The intensity of the signal
is directly proportional to the number shown so the higher the number the greater the signal intensity detected.
The minimum value for modem operation is 11. The quality of the signal is inversely proportionate to the
number, therefore '0' indicates the best quality and a higher number will indicate worse quality. Number 99
indicates that the value cannot be determined.
To quit the function and return to the previous menu press
If the receiver is using the WF card it will be ready for use when [WF] appears on the display. The value
shown represents the signal intensity that the card is receiving. The maximum operating value is set to
-83dbm, and is to be considered indicative as signal quality depends on the ambient in which the device
is located. As the value gets higher the operating conditions will improve.
Certain operators require the data connection to be activated using a protocol which is different to the
standard expected by the receiver.
This condition which will be confirmed by the receiver showing the indication [REQ] for one to two minutes
on the display before closing the call.
A different protocol can be set as follows:
• Enter function "A) SIGNAL" where the signal status for the telephone network is shown.
• Press and hold down
• On the area of the display normally occupied by the numbers the indication of the modality chosen for
the connection will be accompanied by a beep. The indication "SWAP0" means standard protocol will
be used while "SWAP1" indicates an alternative protocol.
• Switch the receiver off and on to make the new setting active.
MENU: CONNECTION (only 2G/3G cards)
This setting establishes which numbers are to be enabled for the data connection. The default setting is
ANYBODY which allows all numbers to access the connection even if they haven't already been associ-
ated with a channel.
If you set the value to 'ADDRESS BOOK' only numbers that are present in the address book, shown by
'REMOTE' in the name field, will be accepted. This filter will limit access to a limited number of specific callers.
*
. After 24 hours of inactivity the modem will be restarted automatically.
, for at least 4 seconds.
ENT
.
ESC
26