QUARTZ DIGITAL RADIO CONTROL WITH PROGRAMMABLE CODE 230V
Description
The S46 230V Radio control system consists of one or more transmitters
and one or more receivers which can be combined to meet the specific
needs of the client.
The receiver model offers the following possibilities: up to 4 channels and a
number of possible combinations equal to 19683, (these are programmable
through the use of a block of 9 three-way dip-switches).
Use
The S46 230V radio control allows the remote activation of electrical and
electronic appliances with its best use in the following areas: automatic
opening systems and in all systems which require remote control activation
(without wires) using secret codes.
Compatibility
• The transmitters are fitted with a jumper "JC" (see drawings 3,4) to
maintain compatibility with receivers of the series non "C".
- Jumper inserted:
Compatible with NON series "C" receivers
- Jumper not inserted: Compatible with series "C" receivers
• The receiver RVQ046100 is a non "C" type receiver therefore
you should make sure that the jumper on the transmitter is
inserted in postion "B"
Transmitter versions
TRQ466200
Pocket size transmitters
TRQ466400
Pocket size transmitters
Receiver versions
RVQ046100
Outdoor receivers (CS922)
Receiver antenna installation
Minimum and maximum range of the radio controls. "Range" is intended to mean
the working distance, measured in free space, between the receiver and the
transmitter with the antenna installed.
The range is therefore closely linked to the technical characteristics of the system
(power and sensibility) and varies according to the characteristics of the site in
which the system is located. It therefore follows that to obtain the best results
from the radio control the installation sites for the receiver and the antenna should
e carefu
b
lly chosen.It is not possible to install 2 receivers at a distance of less
than 1,5 m from each other. It is good practise to position the receiver away from
computer systems, alarm systems and other possible sources of disturbance.
(A bad choice of positioning could compromise the performance of the
receiver).
Antenna
Theinstallationoftheantennaisfundamental;connectedtothereceiveritrepresents
the reception point for the radio control. When installing the antenna the following
points should be observed:
- Only use a tuned antenna connected to the receiver using a coaxial cable
RG58 (impedance 50Ω) with a maximum length of 15m;
- The antenna should be positioned out of doors in the highest possible point,
visible and away from metal structures.
Note: If for some particular reason it is not possible to fit an antenna, a reasonable
performancecanbeobtainedbyconnectinga 2,5mpieceofsinglepoleconductor
wire (Ø1mm.) to the receiver.
4-channel outdoor receivers IP55 (fig.5)
The receiver is in an autdoor case fitted with a 12-way terminal board (printed
circuit CS922) with the following electrical connections: 230Vac between binding
posts 11-12.
RECEPTION FREQUENCY
ATTENTION
The transmission frequency of these products varies
according to the approved frequency and eventual
personalisation in the country of destination.
Country
Frequency Antenna
Only Italy
29,875 MHz ANQ730
Europe
27,195 MHz ANQ727
USA
27,195 MHz ANQ727
+39/0438.404011-401818
+39/0438.401831
Sales.office.it@cardin.it
Sales.office@cardin.it
www.cardin.it
2 channels
4 channels
4 channels
RECEIVER
- local oscillation frequency tolerance ..................... 30p.p.m. from -10° to +55°C
- intermediate frequency........................................................................... 455KHz
- antenna impedance in input ......................................................................... 50Ω
- sensibility (fine signal).................................................................................0.5µV
- local oscillation emission..................................................... <-70dBm (<100pW)
- power supply .........................................................................................230V ac
- maximum power consumption at rest........................................................18mA
- maximum power consumption with activated relay...................................20mA
- maximum commutable power at the relay with load in ac/dc ........... 60VA/24W
maximum voltage ...............................................................................30V ac/dc
- excitation delay/dropout delay ................................................................ 150 ms
SERIAL NUMBER
ZVL114.03
The S46 series conforms to the essential requirements of the directive 99/05/CE and
the technical reference standards have been applied. This product has been tried
and tested in the manufacturer's laboratory, during the installation of the product
follow the supplied indications carefully.
Interchangeable channel modules
In the receivers with container the interchangeable channel modules can only have
the following configurations and must not be mixed:
- from 1 to 4 impulsive relay strips MCC4491R0
- one memory relay strip MCC0381M0
- one timer relay strip MCC0381T0
Receiver installation
Depending on the type of installation, work out the position in which the
programmer will be situated remembering that the site must be:
- a position safe from accidental collision;
- high enough above the ground to be safe from pools of water;
- in a position which the technician can easily reach.
The fixing of the case type receiver is carried out by using "fast-fitting" brackets.
The bracket should be fixed to the wall using two raw plugs (check that it is
plumb to the wall), the case can then be slid onto the bracket and fastened
securely to the wall. The slot-in circuit located towards the bottom of the
case can be easily extracted to facilitate wiring up the device. If any repair
work is necessary the case can be easily extracted by pushing upwards the
action of which will separate it from the bracket.
Electrical connection (fig.5)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the
mains supply;
- a bipolar circuit breaker which leaves at least 3mm. between the contacts
has been installed between the device and the mains;
- the high voltage 230V wires pass through the holes marked "A" and are
routed separately from the low voltage wires which pass through the holes
marked "B" and "C";
- the wires are fastened down using a cable clamp;
- once the wiring is complete the holes through which the wires have passed
have been sealed using silicon;
- the holes which are not used are sealed by inserting the sealing
caps "D".
• Only low voltage circuits may be wired to the external circuit binding
posts .
TRANSMITTERS (Fig.3-4)
In the transmitters each key corresponds to a different channel, with the sole
exception of the two key transmitters where it is possible to have the same
channel for both keys. (single-channel operation).
For double-channel operation which can be obtained using the second key,
set the two-way DIP switch, located separately from the nine-way user code
DIP switch on the printed circuit board. Once the transmitter's functions have
been programmed or recognized, make sure that every STRIP in the outdoor
receiver (which carries the relay) corresponds to the desired function.
PROGRAMMING THE TRANSMITTER USER CODE
The transmitters and receivers are supplied with a block of 3-way
dip-switches with which to program the digital codes for each system.
Programming can be carried out more than once, even after the installation,
thus ensuring the total secrecy of the user code. To ensure an exact match
between the transmitter and receiver codes when programming the following
should possibilities be taken into consideration:
For 2 and 4 key transmitters coupled with receivers with up to 4 channels.
Set the same code in both the receiver and the transmitter using all the 9
available DIPS (19683 possible combinations). It is important to remember
that the receivers can only respond to one command at a time.
IT FOLLOWS THEREFORE THAT MULTIPLE FUNCTIONS CANNOT BE
USED CONTEMPORANEOUSLY.
TECHNICAL SPECIFICATIONS
TRANSMITTERS
- carrier frequency tolerance.................................... 30p.p.m. from -10° to +55°C
- band width................................................................................... 10KHz/± 5KHz
- apparent radiated power ............................................-10...-7dBm (100-200µW)
- apparent power harmonic products ........................................ <-64dBm (<1nW)
- power output adjacent channel (± 10 kHz)........................... <-37dBm (<0.2µW)
- modulation............................................................................................. AM/ASK
- signal modulation .......................................................................PCM, 1.3ms/bit
- power supply (Alkaline battery GP23A) ............................................. 12V ± 10%
- maximum power consumption................................................................ <38mA
- operating temperature range..........................................................- 20... +70°C
- relative humidity ........................................................................................ <95%
MODEL
SERIES
S46
230V
21-09-2001
1 channel
1 channel ON-OFF
1 channel 0,5 to 120 Sec.
DATE

Werbung

loading

Inhaltszusammenfassung für Cardin Elettronica ZVL114.03

  • Seite 1 CARDIN ELETTRONICA spa SERIAL NUMBER MODEL DATE SERIES Via Raffaello, 36- 31020 San Vendemiano (TV) Italy ZVL114.03 230V 21-09-2001 Tel: +39/0438.404011-401818 The S46 series conforms to the essential requirements of the directive 99/05/CE and Fax: +39/0438.401831 the technical reference standards have been applied. This product has been tried email (Italy): Sales.office.it@cardin.it...
  • Seite 2 CARDIN ELETTRONICA spa ART.-NR. SERIE MODELL DATUM Via Raffaello, 36- 31020 San Vendemiano (TV) Italy ZVL114.03 230V 21-09-2001 Tel: +39/0438.404011-401818 Die Serie S46 entspricht den von der Bestimmung 99/05/CE festgelegten grundsätzlichen Fax: +39/0438.401831 Anforderungen und bei ihr wurden die technischen Bezugsnormen angewandt.
  • Seite 3 Description : Dimensioni d'ingombro contenitore Drawing number : DM0042 CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831 1 2 3 4 5 6 7 8 9 Product Code : RX046 CH-D All rights reserved.

Diese Anleitung auch für:

S46-serie230v