Herunterladen Inhalt Inhalt Diese Seite drucken

Instructions For Care; Technical Data - Eschenbach ridoMED serie Bedienungsanleitung

Lupenbrille
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
1. Grind the correction lenses to 22 mm.
2. Attach correction lenses using the
attachment rings to the eye-side of
the system.
c If eye-side correction is not necessary,
the eyepiece cups [5] can be fitted
with caps [6].
If required, the adjustment supple-
ment in the Eschenbach brochure "Ad-
justment of magnifying viewing aids"
Article No. 162510 gives additional
information.
3. The focusing ring can be rotated [7] for
accurate focusing.
c The focusing positions in the system
can be used to compensate spherical
correction (Dioptric compensation
± 5 Dpt.).
The focusing ring is difficult to rotate
in order to prevent the focus setting
from changing by itself.

Instructions for care

The magnifying/telescopic spectacles
should be kept in their case when not in
use.
Clean the lenses with a soft, lint-free cloth
(e. g. lens cleaning cloth), for harder to
remove dirt (e. g. finger prints) slightly
dampen the cloth.

Technical data

ridoMED
Magnification
Viewing field
values *
)
Near (mm)
Viewing angle
Working distance
(mm)
Lens Ø
Weight
Dioptric
compensation
teleMED
Magnification
Viewing field
)
values *
Far (mm)
Viewing angle
Working distance
(mm)
Lens Ø
Weight
Dioptric
compensation
*) The effective viewing field in the Galilei
systems is dependent on the distance be-
tween the eye and the eyepiece. Therefore,
the viewing field values given are average
values (Viewing angle was measured at
HSA [cornea-lens distance] 10 mm).
- 7 -
16362 16363 16364
2.5 ×
3.0 ×
4.0 ×
91/350 54/200 34/250
15.0°
12.5°
8.0°
≈ 350 ≈ 200 ≈ 250
23 mm
70 g
± 5 dpt.
1634
16344
3 ×
4 ×
160/1000
130/1000
9.5°
7.5°
700 ~ ∞
780 ~ ∞
23 mm
70 g
± 5 dpt.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis