Step 5: Connect drain hose
By default, the drain hose is attached to the left-
hand side of unit (when you're facing the back
of the unit). However, it can also be attached to
the right-hand side. To ensure proper drainage,
attach the drain hose on the same side that your
refrigerant piping exits the unit.
Wrap the connection point firmly with Teflon
tape to ensure a good seal and to prevent leaks.
Remove the air filter and pour a small amount
of water into the drain pan to make sure that
water flows from the unit smoothly.
NOTE ON DRAIN HOSE
PLACEMENT
Make sure to arrange the drain hose
according to the following figures.
.
DO NOT kink the drain hose.
DO NOT create a water trap.
DO NOT put the end of drain hose in
water or a container that will collect
water.
CORRECT
Make sure there are no kinks
or dent in drain hose to ensure
proper drainage.
NOT CORRECT
Do not place the end of the
Kinks in the drain hose
drain hose in water or in
will create water traps.
containers that collect water.
This will prevent proper
drainage.
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks
you must plug the unused
drain hole with the rubber
plug provided.
1. All wiring must comply with local and national
2. All electrical connections must be made
3. If there is a serious safety issue with the power
4. Power voltage should be within 90-110% of
5. If connecting power to fixed wiring, install a
6. If connecting power to fixed wiring, a switch
7. Only connect the unit to an individual branch
8. Make sure to properly ground the air conditioner.
NOT CORRECT
9. Every wire must be firmly connected. Loose
Kinks in the drain hose
will create water traps.
10.
11.
NOT CORRECT
12.
80
BEFORE PERFORMING ANY
ELECTRICAL WORK, READ THESE
REGULATIONS
electrical codes, regulations and must be
installed by a licensed electrician.
according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor
units.
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
rated voltage. Insufficient power supply can
cause malfunction, electrical shock, or fire.
surge protector and main power switch with
a capacity of 1.5 times the maximum current
of the unit.
or circuit breaker that disconnects all poles and
has a contact separation of at least 1/8in (3mm)
must be incorporated in the fixed wiring. The
qualified technician must use an approved
circuit breaker or switch.
circuit outlet. Do not connect another
appliance to that outlet.
wiring can cause the terminal to overheat,
resulting in product malfunction and possible fire.
Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts
within the unit.
If the unit has an auxiliary electric heater, it must
be installed at least 1 meter (40in) away from
any combustible materials.
To avoid getting an electric shock, never touch
the electrical components soon after the power
supply has been turned off. After turning off
the power, always wait 10 minutes or more
before you touch the electrical components.