Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Characteristics; Installation - Ariston 353 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 82
EN
Electromechanical water heaters are sold with the thermal sanitisation cycle disabled (default setting). If, for some
reason, any of the above "conditions in favour of the proliferation of Legionella" occurs, it is strongly recommended to
enable this function according to the instructions found in this manual [see <<Activating the "thermal disinfection
cycle" (anti-legionella)>>].
However, the thermal disinfection cycle does not kill all Legionella bacteria in the storage tank. It follows that if the
function is disabled, the Legionella bacteria may reoccur.
Note: when the software performs the thermal sanitisation treatment, it is likely that the power consumption of the water
heaters increases.
Caution:
the water temperature in the tank can cause immediate serious burns when the software runs the thermal
disinfection treatment. Children, disabled persons and the aged are particularly at risk of burns. Check
the water temperature before taking a bath or shower.

TECHNICAL CHARACTERISTICS

For the technical specifications, refer to the nameplate (the nameplate is located next to the water intake/outlet pipes).
Product range
Weight (kg)

Installation

Model
SMART
Qelec (kWh)
Qelec, week, smart (kWh)
Qelec, week (kWh)
Load profile
L
wa
η
wh
V40 (L)
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this
manual) are defined in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation 812/2013,
are not intended to be used in such assemblies.
The device is equipped with a smart function that allows you to adapt the consumption to the user profiles. If operated
correctly, the device has a daily consumption of "Qelec*(Qelec,week,smart/Qelec,week)"less than that of an equivalent
product with no smart function" .
The data shown in the energy label refer to the product installed vertically.
This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335-2-21.
The CE marking of the appliances attests its conformity to the following EC Directives, of which it satisfies
the essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RoHS2 Risk of Hazardous Substances: EN 50581.
- ErP Energy related Products: EN 50440.
20
Table 3 - Product information
50
17
Vertical Horizontal Vertical Horizontal Vertical Horizontal
X
6,893
7,468
24,558
-
29,678
-
M
M
40,0%
33,0%
65
65
80
22
Refer to the nameplate
X
X
7,323
7,113
25,435
25,552
32,942
33,330
M
M
15 dB
40,0%
40,0%
92
87
100
26
X
X
7,455
7,249
26,002
25,879
33,778
34,823
M
M
40,0%
40,0%
130
103