LEGIONELLA BACTERIA FUNCTION
Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries'
disease is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stagna-
tion should be avoided; it means the water heater should be used or fl ushed at least weekly.
The European standard CEN/TR 16355 gives recommendations for good practice concerning the preven-
tion of Legionella growth in drinking water installations but existing national regulations remain in force.
This electronic storage water heater is sold with a thermal disinfection cycle function enabled by default.
Every time the product is switched on and every 30 days, the thermal disinfection cycle run to heat the
water heater up to 60°C.
Warning: when this software has been carrying out the thermal disinfection treatment, water temperature
can cause burns. Feel water before bathing or showering.

TECHNICAL CHARACTERISTICS

For the technical specifi cations, refer to the nameplate (the nameplate is located next to the water in-
take/outlet pipes). Product can't work in "off peak" installation.
Product range
Weight
Installation
Model
SMART
Q
kWh
elec
Q
kWh
elec , week, smart
Q
kWh
elec , week,
Load profi le
L
wa
η
wa
V40
Volume available
The power consumption data in the table and the other information given in the Product Fiche (Annex A to
this manual) are defi ned in relation to EU Directives 812/2013 and 814/2013.
Products which do not have the label and Product Fiche required for boiler/solar power confi gurations
pursuant to regulation 812/2013 may not be used in such installations.
The appliance has a smart function which adapts consumption to the user's use profi le.
If used properly, the appliance has a daily consumption of "Qelec (Q
than that of an equivalent product without the smart function.
The data on the energy label apply to the product when installed vertically
The appliance is conforming with international electrical safety standard IEC 60335-1;
IEC 60335-2-21.
The CE marking applied to the appliance certifi es that it conforms with the essential requirements of
the following European Directives:
- Low voltage directive (LVD): EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- Electromagnetic compatibility (EMC): EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RED directive. ETSI 301489-1, ETSI 301489-17
- ROHS 2 directive: EN 50581.
- ErP Energy related Products: EN 50440.
- The CE Declaration of Conformity is available at the following address:
http://www.aristonthermo.com/en/download-area
30 / EN
TABLE 1 - PRODUCT INFORMATION
45
45 DRY
kg
21
Vertical
Vertical
x
7,290
25,234
24,963
32,166
30,985
M
40,0%
39,3%
l
77
l
45
65
21
27
Vertical
Refer to the nameplate
x
x
7,419
7,443
25,456
34,333
M
M
15 dB
40,0%
77
110
45
65
65 DRY
80
27
32
Vertical
Vertical
x
x
7,449
7,099
27,359
26,560
34,951
31,860
M
M
40,0%
39,6%
110
115
65
80
/Q
elec, week, smart
elec, week
80 DRY
32
Vertical
x
7,452
27,663
34,992
M
39,8%
115
80