ERROR CODES
If there is an error, error code will be showed at heater displays.
E1 : Cooling Fan is disabled, call authorized service agents.
E3 : Supply coltage is over than rated values, turn the hob off by touching
until "H" disappears for all zones, turn the hob on by touching
to use. If same error is seems again, call authorized service agents.
E4: Supply frequency is different from rated values, turn the hob off by touching
wait until "H" disappears for all zones, turn the hob on by touching
continue to use. If same error is seems again, call authorized service agents.
E5 : Hob inside temperature is too high, turn the hob off by touching
heaters cool down.
E6: Communication error between touch control and heater, call authorized
service agents.
E7: Coil temperature sensor is disabled, call authorized service agents.
E8: Cooler temperature sensor is disabled, call authorized service agents.
E9: Calibration error, call authorized service agents.