PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
• Caution! The installation of both anti-derailment buffers is absolutely obbligatory before starting programming.
• Make sure that the safety devices are at rest otherwise you will not be able to enter programming.
• Open the "Standard wiring diagram" which is folded inside the last page of this manual and carry out the programming procedure.
Caution: If the symbol
after 3 minutes has passed since the programmer
was powered up, the gate will start moving auto-
matically (after the warning lights have flashed for
10 seconds) to the completely closed position
(automatic repositioning).
Dip-switch settings DS1
Sequential command TD/CH1
Dip 1 "ON" = Sequential command "open-close"
Travel direction inversion only during closing.
Dip 1 "OFF" = Sequential command "open-block-close-block"
Automatic reclosing (DIP 2)
Dip 2 "ON" = Automatic reclosing enabled
Dip 2 "OFF" = Automatic reclosing disabled
Pre-flashing (DIP 3)
Dip 3 "ON" = Pre-flashing activated
Dip 3 "OFF" = Pre-flashing excluded
Warning light output (DIP 4)
Dip 4 "ON" = Warning light output intermittent
Dip 4 "OFF" = Warning light output fixed
Indicator light (DIP 5)
Dip 5 "ON" = Indicator light intermittent
Dip 5 "OFF" = Indicator light fixed
*
Theindicatorlightflashesslowlyduringopening,rapidlyduringclosing;remains
lit when the gate is blocked but not completely closed and is off when the gate
is completely closed.
FTCI (DIP 6)
Dip 6 "ON" = FTCI also active when the gate is blocked
If the photocells are in alarm and the gate is blocked, no movement commands
will be accepted (even opening commands).
Dip 6 "OFF" = FTCI active only during closing
In both cases activating the FTCI safety device during the closing stage will
force travel direction inversion.
FTCI test (DIP 7)
Dip 7 "ON" = FTCI test enabled
Dip 7 "OFF" = FTCI test disabled
If you enable the security test you will have to connect both the transmitter and
the receiver to the controlled load output (CTRL 30 Vdc).
When the test is enable one second will pass between receiving a command
and carrying it out.
Motor installation (DIP 8)
Dip 8 "ON" = Right-hand motor installation
Dip 8 "OFF" = Left-hand motor installation
Manual operating mode (DIP 9)
Dip 9 "ON" = Manual mode enabled
Dip 9 "OFF" = Manual mode disabled
appears on the display
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
ON
*
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE "PAUSE" SYMBOL
WILL APPEAR INDICATING THAT YOU ARE
IN THE PAUSE PROGRAMMING MODE
ATTENTION! IF THE GATE MOVES
IN THE OPENING DIRECTION DIP
8 HAS BEEN SET INCORRECTLY.
PRESS "PROG" AGAIN TO
CANCEL THE PROCEDURE , SET
DIP 8 CORRECTLY AND REPEAT
THE PROGRAMMING
PROCEDURE.
WHEN THE GATE REACHES THE COMPLETELY CLOSED POSITION IT INVERTS THE TRAVEL
DIRECTION AND AFTER MOVING FOR A FEW CENTIMETRES IT WILL CLOSE AGAIN TO
CONFIRM THE COMPLETELY CLOSED POSITION.
AT THIS POINT THE OPENING MANOEUVRE WILL START, AT LOW SPEED, SO AS TO FIND THE
COMPLETELY OPEN POSITION; AFTER IT HAS TRAVELLED FOR ABOUT HALF A METRE THE
GATE WILL STOP FOR A SECOND TO MEASURE THE INERTIA AND THEN MOVE AGAIN. ONCE
IT HAS ARRIVED AT THE COMPLETELY OPEN POSITION, IT INVERTS THE TRAVEL DIRECTION
FOR A FEW CENTIMETRES AND THEN CONTINUES OPENING IN ORDER TO CONFIRM THE
COMPLETELY OPEN POSITION.
AFTER HAVING CARRIED OUT THIS MANOEUVRE THE GATE WILL CLOSE AGAIN. IT WILL STOP
FOR A SECOND TO MEASURE THE INERTIA AND THEN CARRY ON CLOSING. ONCE IT HAS
REACHED THE COMPLETELY CLOSED (4–5 CM FROM THE MECHANICAL TRAVEL BUFFER) THE
CONTROL LOGIC WILL CARRY OUT A COMPLETE OPENING AND CLOSING CYCLE IN ORDER TO
CALIBRATE THE CURRENT SENSOR.
THE OPERATION HAS NOT
SUCCEEDED. YOU WILL HAVE
TO REPEAT THE
PROGRAMMING PROCEDURE.
IF THIS SYMBOL APPEARS FOR A FEW SECONDS, THE PROGRAMMER IS
ONLY MANAGING 2 ENCODER SIGNALS (PREVIOUS ENCODER CARD
MODEL (4 WIRES) OR A DEFECTIVE 5-WIRE ENCODER CARD.
ATTENTION! If you change the dip settings during normal operation you
will have to memorise them. When the display is off press the "PROG"
button once. The symbol "_diP_" will appear on the display confirming
correct memorisation.
CURRENT SENSOR
The programmer checks the electrical input to the motor, detecting any
eventualincreaseineffortabovethenormaloperatinglimitsandintervenes
as an additional safety device.
When the sensor intervenes the gate will automatically invert for 10 cm,
both in the closing as well as the opening direction, to free the obstacle
it will then stop for 3 minutes and then continue moving in the original
direction after a 10 second preflashing period has elapsed.
16
1...4... sec.
PRESS PROG
THE PAUSE TIME COUNT
WILL START INDICATED BY
THE "PAUSE" SYMBOL
FLASHING ON THE DISPLAY
PRESS PROG
THE PAUSE TIME COUNT
ENDS AND THE GATE CLOSES
SLOWLY IN ORDER TO FIND
THE COMPLETELY CLOSED
POSITION.
WHEN THE GATE REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER SAVES THE PARAMETERS
AND QUITS THE PROGRAMMING MODE