Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

ACTION
WHAT/WHO
Instruct
New operator
Check
High pressure hose
Check
Pressure gauge
Check
Detergent suction
Clean
Water filter
Clean
Fine sand
filter
Clean
Turbo Laser
filter
Adjust
By-pass valve
Check
Gaskets
Perform
Oil change
Symptoms
High pressure cleaner
does not start.
High pressure cleaner
stops suddenly.
32

CHECK LIST

WHEN/HOW OFTEN
Before operator uses
high pressure cleaner
During daily use
During daily use
Daily - by means of
detergent
Weekly/as needed
As needed
As needed
Every other month
Every other month
After 300 hours
operation - at least
once a year
FAULTFINDING
Cause
Selector not
activated.
High pressure cleaner not
connected to the power line.
Fuse burnt out.
Missing voltage in plug.
Fuse burnt out.
Low voltage.
Motor too warm.
Operating pressure too high
(nozzle dirty, wrong nozzle).
HOW
Let operator read
instruction guide
Leaks? - call
service engineer
Too high/too low? -
call service engineer
Lack of suction/leaks? -
call service engineer
See maintenance
See maintenance
See maintenance
Call service engineer
Leaks? - call
service engineer
See maintenance
Corrective action
Turn selector to pos. "AUT" or "1".
Put in the plug, switch on
the main switch.
Change fuse. If fuse burns out again,
contact service department.
Connect voltage acc. to el. diagram.
Change fuse. If fuse burns out again,
contact service department.
Extension cable too long, contact
service department.
Turn selector to pos. "0"
and wait 15 min. Restart the machine.
Clean/change nozzle (see technical
data).