Herunterladen Inhalt Inhalt Diese Seite drucken

Check List For Maintenance; Fault Finding - Nilfisk-Advance Gerni N/G-6400A Betriebsanleitung

Inhaltsverzeichnis

Werbung

ACTION
WHAT/WHO
Instruct
New operator
Check
High pressure
hose
Check
Pressure
gauge
Check
Detergent
suction
Clean
Water filter
Clean
Fine sandfilter
Check
Machine for leaks
Check
Oil level -
pump
Perform
Oil change - pump
Adjust
Oil burner
Clean
Boiler/coil
Perform
Descaling
Check
Thermostat
Indicator lamp
.
Does not light up.
Lights up
Lights up.
Lights up.
Lights up.
Lights up.
32
CHECK LIST
WHEN/HOW OFTEN
Before operator uses
high pressure cleaner
During daily use
During daily use
Daily - by means of
detergent
Weekly/as needed
As needed
Every other month
During daily use
After 300 hours
operation - at least
once a year
Twice a year/
as needed
Yearly/as needed
For pressure increase
over 5 bar
Every other month

FAULT FINDING

Cause
Cable pulled out of plug.
No supply voltage.
No supply voltage on the
print plate transformer.
Cover not correctly closed.
The supply voltage has
been disconnected.
The motor is overloaded,
The coil too hot.
Lack of fuel.
pressure cleaner.
The water tap is not open.
No water supply.
The phase sequence in the
electric plug is incorrect.
No flame.
HOW
Let operator read
instruction guide
Leaks ? - call
service engineer
Too high/too low ? -
call service engineer
Lack of suction/leaks ? -
call service engineer
See maintenance
See maintenance
Leaks ? - call
service engineer
See maintenance
See maintenance
Call service engineer
Call service engineer
See maintenance
Temperature too high/low ?
- call service engineer
Corrective action
Refit electric cable in the plug.
Replace fuses in the electric board.
Replace the fuse in
the control voltage.
Close cover correctly and re-start the
high pressure cleaner.
Restart the high pressure cleaner.
Cool the motor and restart the
high pressure cleaner.
Add diesel oil and estart the high
Turn on the water and restart the
high pressure cleaner.
Fit the water inlet hose on the
high pressure cleaner and restart.
Change phase sequence in plug
and restart high pressure cleaner.
Switch off and restart the high pressure
cleaner.Replace the fuel filter and restart
the high pressure cleaner.If unable to reset
machine -contact the service department.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gerni n/g-6600a

Inhaltsverzeichnis