F3301/F33C1/F33S1
7.4

Connection assignment analog signal redudant opposing

2 round connectors option, for example, in combination with ELMS1
overload protection (F73S1). Version acc. the requirements for func-
tional safety acc. maschines directive 2006/42/EG.
7.5

Connection assignment CANopen

Round connector M12x1, 5 pin
The cable shield is connected to the GND of the tension link.
The shield of the accessory cables is connected to the knurled
nut and therefore the GND of the tension link. Only shielded and
low-capacity cables must be used for extending. The allowed
maximum and minimum lengths of the cable are specified in the
ISO 11898-2. The shield must also be properly connected.
34
Round connector M12x1, 4 pin
Power supply: UB+
Power supply:
0V/UB-
Signal: channel 1
Signal: channel 2
Shield
BD_BE_973 b
4...20 mA/
20...4 mA (redundant)
Round
Round con-
connector
nector 2
1
1
1
3
3
4
-
-
4
Housing
Housing
®
Shield
UB+ (CAN V+)
UB- (CAN GND)
Bus-Signal CAN-High
Bus-Signal CAN-Low
1
2
3
4
5