TROUBLESHOOTING
Troubleshooting the sauna heater
Table 1: Troubleshooting the sauna heater
Symptom
Possible cause
Heater not working
Main power switch
is off.
Heater not working
Fuse blown
Heater not working
Temperature cut-
out has been activ-
ated. For more de-
tails, see The sec-
tion called Temper-
ature cutone, Page
5.
Temperature cutone
The temperature cut-out of the sensor is to protect the compon-
ents, tubular elements and woodwork in the sauna from overheat-
ing. If the sensor's temperature cut-out is activated, electricity
to the control panel will be cut off. When the temperature in the
sauna goes down, it can be reset. The cause of the overheating
must be established before it resets. Use an object such as a pa-
per clip to press the springloaded button to reset (see Figure 6,
Page 5).
Figure 6: Resetting the sensor temperature cut-out
SPARE PARTS LIST
Remedy
Switch on.
Replace fuse.
Check and remedy
the cause of tem-
perature cut-out ac-
tivation.
If you are unsure
why the temperat-
ure cut-out was ac-
tivated, contact an
electrician.
Figure 7: Spare parts
1.
2.
3.
4.
1
2
3
4
9600 177 / 8 kW, 9600 0178 / 6 kW
9600 0091
9600 0723
9600 0041
5