Herunterladen Inhalt Inhalt Diese Seite drucken

Global Properties; Advanced Properties - tbs electronics Expert Modular Bedienerhandbuch

High precision modular battery monitor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

F9.8
Show bank 3 voltage. Only available when F3.0 is set to AUX.BAT.
Default: ON
F9.9
Auto hide parameter. The default setting will allow the bottom parameter to only show
for 120 seconds after the Expert Modular has been accessed. This will keep the display
clean under normal conditions, which might be preferred by less technical end users.
When auto hide is set to OFF, the bottom parameter row is always visible.
Default: 120sec
6.7

Global properties

F10.0
Backlight timer. Represents the duration of backlight activation in seconds after key-press.
The backlight can also be set to be always "ON" or always "OFF".
Default: 30sec
F10.1
Backlight auto on. When set to "ON", The backlight is automatically activated when the
charge / discharge current exceeds 1Amp.
Default: OFF
F10.2
Alarm contact polarity. Enables selection between a normally open (NO) or normally
closed (NC) contact.
Default: N/O
F10.3
Temperature units. Enables selection between degrees Celsius (°C) and degrees
Fahrenheit (°F) in the temperature readout.
Default: °C
6.8

Advanced properties

A01
Auto-sync mode. Choose which mode to use to automatically synchronize the Expert
Modular with your battery when it is fully charged. The default mode is STANDRD which is
the preferred setting for most applications. The setting LEGACY represents an auto-sync
mode as used in the Expert Pro and Lite battery monitors. This mode can be selected
when the installer wishes to have more control over the auto-sync conditions. These
conditions can be set in Functions A02, A03, A04 and A05 once A01 is set to LEGACY. Only
when the conditions of A02 and A03 are both met during the time period set in A04, the
battery is considered fully charged and the SoC value is set to 100%.
Default: STANDRD
A02
Auto-sync voltage (will only show when A01 is set to LEGACY). The battery voltage must
be above this level to consider the battery as fully charged. This value must be slightly
below your battery charger's float voltage (0.1 – 0.3V), which is the last stage of the
charging process. The default value can be multiplied by 2 or 4 if respectively 24V or 48V
systems are connected to the Expert Modular.
Default: 13.2V
Range: OFF / ON
Range: OFF / 5 – 300sec
Range: OFF / 5 – 300sec / ON Step size: variable
Range: OFF / ON
Range: N/O – N/C
Range: °C / °F
Range: STANDRD / LEGACY
Range: 7.0 – 70.0V
24
Step size: 0.1V

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis