Battery bank 3 properties

F3.0
Battery bank 3 function. Set the function for the battery bank 3 (+B3) input.
Default: DISABLE
F3.1
Battery bank 3 type (will only show when F3.0 is set to AUX.BAT). Choose the chemistry
type of your battery.
Default: AGM
F3.2
Battery bank 3 name (will only show when F3.0 is set to AUX.BAT). Choose a display name
for your battery bank that comes nearest to your application.
Default: AUX.2
6.4

System properties

F4.0
Time remaining averaging filter. Specifies the time window of the moving averaging filter.
There are four settings, where setting 0 gives the fastest Time remaining readout
response and setting 3 the slowest. The best setting will depend on the type of battery
load and your personal preference.
Default: 1
F4.1
Enable maintenance hour count. When set to OFF, only the operating hours are
accumulated which starts once the battery monitor is being powered up (unless Functions
F2.0 or F3.0 are set to HOURCNT, so that operating hours are only counted when the +B2
or +B3 input is 'high'). When set to ON, the counted hours are being subtracted from the
Maintenance interval hours set in Function F4.2.
Default: OFF
F4.2
Maintenance interval. Choose a time schedule for maintenance. When Function F4.1 is set
to ON, the accumulated operating hours are being subtracted from the maintenance
interval hours set in this Function. A maintenance alarm message will automatically
appear on the display, once the maintenance interval has reached 0 hours.
Default: 5000h
6.5

Alarm properties

The Expert Modular offers four independent configurable alarms. This offers great flexibility for the
installer. Whether you wish to configure four completely different alarm types, or trigger an
individual alarm on for example four different State of Charge values, there are almost limitless
possibilities. Especially when adding an optional Alarm Output Expander to your Expert Modular
system. This will allow each alarm to trigger a dedicated alarm relay.
F5.0
Alarm 1 type. Choose which parameter will trigger this alarm. The default 'SOC.Low' will
trigger an alarm when the State of Charge has dropped below a bottom limit. All available
alarm types are described in table 10.
Default: SOC.Low
Range: see table 9
Range: see table 7
Range: see table 8
Range: 0 – 3
Range: OFF / ON
Range: 100 – 100000h
Range: see table 10