Electric connections accessories
Important:
Because of polarity sensitivity, always connect contacts X1-1 to X1-1 and contacts X1-2 to X1-2. Never connect
X1-1 and X1-2.
230 V
50 Hz
For M (Master):
set parameter 9 to 0 (= factory setting).
Display shows ventilation mode 1, 2 or 3.
A
=
Multiple switch
B
=
2-pole connector
M
=
Renovent Excellent (Master)
C1 t/m C*
=
Renovent Excellent (Slave); couple not more than 10 appliances through Ebus
Parameter
Description
8
Communication type
9
eBus address
230 V
50 Hz
For C1 (Slave1):
set parameter 9 to 1 (= Slave 1).
Factory
Range
setting
0t ( = Opentherm)
eBus
eBus
0 = master
0
1 - 9 = slave 1 - 9
Renovent Excellent
Chapter 11
A maximum of 10 appliances
(1 Master + 9 Slave max.)
230 V
50 Hz
For C2 (Slave2):
Set parameter 9 to 2 (= Slave 2).