Noise Emission / Vibration
The indication of noise emission is measured according to DIN 45 635, part 21.
The level of acoustic pressure on the work place could exceed 85 dB (A); in
this case protection measures must be taken.
Wear ear protectors!
The typical hand-arm vibration is below 2.5 m/s².
Measured values determined according to EN 61 029.
The declared vibration emission level represents the main applications of the
tool. However if the tool is used for different applications, with different
accessories or poorly maintained, the vibration emission may differ. This may
significantly increase the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into
account the times when the tool is switched off or when it is running but not
actually doing the job. This may significantly reduce the exposure level over
the total working period.Identify additional safety measures to protect the
operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
auto-stop brushes
In order to protect the motor, this power tool is equipped with auto-stop
brushes. When the carbon brushes are worn out, the machine switches itself
off. In this case both brushes must be replaced at the same time with original
brushes by an electrical specialist.
In addition there is a service indicator on the motor
cap, which indicates in advance that the machine is
about to shut down due to worn carbon brushes.
After the indicator lights up, you can use the tool for
approximately 1 day. Then the carbon brushes
should be replaced.