AXIS A1001 Network Door Controller

Requirements for UL Compliance

This section contains information and instructions required for UL compliance. To make sure the
installation is UL compliant, follow the instructions below in addition to the general information
and instructions provided throughout this document. In cases where pieces of information
contradict each other, the requirements for UL compliance always replace general information
and instructions.
Supported Readers
Compatibility with the following RS485 readers has been verified by UL: HID iClass RK40,
HID SmartID 8031 DSHM, and AptiqQ MTMSK15.
Safety Instructions
The Axis product shall be installed and serviced by a factory trained professional.
The Axis product shall be installed within the protected premises (secured area).
The Axis product shall be mounted indoors. Outdoor use has not been evaluated or
approved by UL.
All interconnecting devices shall be UL Listed and Class 2 power limited.
All wiring methods shall be performed in accordance with NFPA70, local codes and
authorities having jurisdiction.
When the Axis product has reached the end of its useful life, dispose of it according
to local laws and regulations. The product should not be disposed of together with
household or commercial waste. See Disposal and Recycling on page 3.
Battery
-
The 3.0 V lithium battery used by the Axis product is a UL Recognized
component. (Type: BR2032, diameter: 20 mm (0.78 in), Axis part number:
38118, manufacturers: Rayovac, Panasonic, Renata.)
-
Users shall not replace the battery. If the battery needs replacing,
a factory trained service professional shall contact Axis support
at www.axis.com/techsup for assistance.
-
Used batteries shall be disposed of according to local laws and regulations,
which may vary from state to state. Waste BR lithium cells are neither listed
nor exempted from the USEPA hazardous waste regulations. Waste BR lithium
batteries can be considered reactive hazardous waste if there is a significant
amount of unreacted, or unconsumed lithium remaining. For information
about how to dispose of used lithium batteries, contact your local authority
for waste disposal.
Specifications
Operating Conditions
-
Temperatures beyond 0 °C to 49 °C (32 °F to 120 °F) has not been verified
as part of UL 294.
Wire Area