Herunterladen Inhalt Inhalt Diese Seite drucken

Axis Communications A1001 Installationsanleitung Seite 23

Netzwerk-tür-controller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 79
Power Lock Connector
4-pin terminal block for powering one or two locks (DC output). The
lock connector can also be used to power external devices.
Connect locks and loads to the pins according to the hardware pin chart
generated through the hardware configuration.
Function
Pin
1, 3
0 V DC (-)
2, 4
0 V DC,
floating, or
12 V DC
Power & Relay Connector
6-pin terminal block with built-in relay for:
• External devices
• Auxiliary power (DC output)
• 0 V DC (-)
Connect locks and loads to the pins according to the hardware pin chart
generated through the hardware configuration.
Function
Pin
1, 4
0 V DC (-)
2–3
Relay
5
12 V DC
6
24 V DC
AXIS A1001 Network Door Controller
Notes
For controlling up to two 12 V locks. Use
the hardware pin chart. See Configure
the Hardware on page 27.
Notes
For connecting relay devices. Use the
hardware pin chart. See Configure the
Hardware on page 27.
The two relay pins are galvanically
separated from the rest of the circuitry.
For powering auxiliary equipment.
Note: This pin can only be used as
power out.
Not used
23
Specifications
0 V DC
12 V DC
Max total load = 500 mA
Specifications
0 V DC
Max current = 700 mA
Max voltage = +30 V DC
Max voltage = +12 V DC
Max load = 500 mA

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis