Herunterladen Inhalt Inhalt Diese Seite drucken

Axis Communications A1001 Installationsanleitung Seite 17

Netzwerk-tür-controller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 79
Digital output – For connecting, for example, reader beepers and reader LEDs.
For specifications, see page 20.
Door Connector
Two 4-pin terminal blocks for connecting door monitoring devices and request to exit (REX) devices.
For specifications, see page 21.
Auxiliary Connector
4-pin configurable I/O terminal block. Use with external devices, in combination with, for example
tampering alarms, event triggering and alarm notifications. In addition to the 0 V DC reference
point and power (DC output), the auxiliary connector provides the interface to:
Digital input – An alarm input for connecting devices that can toggle between an open
and closed circuit, for example PIR sensors or glass break detectors.
Digital output – For connecting external devices such as burglar alarms, sirens or lights.
Connected devices can be activated by the VAPIX® application programming interface or
by an action rule.
For specifications, see page 21.
External Power Inputs
NO TICE
NO
NO
TICE
TICE
The product shall be connected using a shielded network cable (STP). All cables connecting
the product to the network shall be intended for their specific use. Make sure that the
network devices are installed in accordance with the manufacturer's instructions. For
information about regulatory requirements, see Electromagnetic Compatibility (EMC) on
page 2.
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited
power source (LPS) with either a rated output power limited to ≤100 W or a rated output current
limited to ≤5 A. For specifications, see page 22.
Network Connector
RJ45 Ethernet connector. Supports Power over Ethernet (PoE). For specifications, see page 22.
Power Outputs
Power Lock Connector
4-pin terminal block for connecting one or two locks. The lock connector can also be used to power
external devices. For specifications, see page 23.
Power & Relay Connector
6-pin terminal block for connecting power and the door controller's relay to external devices such
as locks and sensors. For specifications, see page 23.
AXIS A1001 Network Door Controller
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis