On your new TT20/21 the work with controlling the air input has been simplified so there is only
one knob/damper (below the door).
Between the left position and the middle position you have the normal area where you control the
air input.
No air input = left position and
Maximum air input = middle position.
As help for lighting the control knob/damper can be pushed down a little and pushed completely
to the right. This start help adds some air from below and ensures faster lighting. After a few
minutes the control knob/damper is returned to the normal position (between the left and middle
position).
Lighting and continuous firing at CE/EN-testing
1. The damper/start-up device can be opened (the knob is pushed down and to the right) for a
few minutes at lighting. Put about 12-15 kindling sticks (dia. 2-5 cm) in the bottom of the stove,
laid in a criss-cross pattern as a log house. Put 2 firelighters in the middle and light them.
2. Leave the door ajar so there is an opening of about 1 cm (TT21 see page 66). Leave the stove
like that for about 8-10 minutes before you close the door completely. Stay by the stove as long
as the door is ajar.
3. When the fire has burned to embers (there are no more flames) open the door gently so the
ash is not whirled out through the door. Gently spread out the embers with a poker so they are
even.
4. Put 2-3 pieces of firewood in the stove, about 1,6 to 2,0 kg total. The pieces are put in the bot-
tom of the stove and parallel to the front of the stove with equal distance to the stove's sides and
with mutual distance of about 1 cm. The front piece is best lit if it has a split side that is turned
to the door and one in the embers. Close the door completely immediately. Make sure you don't
overfill the chamber, max.15 cm from the bottom plate of the combustion chamber.
5. The knob/damper is opened so it is about 2/3 open (between the left and middle position)
and after about 2 minutes the damper is set to about 1/3 open. How much the damper should be
open depends on the individual chimney's draught, but the flames should now stabilise to a calm
fire.
6. When the wood has burned to embers (after about 45-60) you start again from point 3.
MAINTENANCE – always use original parts
Maintenance and cleaning of the stove should only be performed when the stove is cold.
The daily maintenance is limited, but once a year the stove should get thorough maintenance.
The combustion chamber should be cleaned for ashes and soot and the door hinges and the clo-
sing mechanism should be lubricated with copper grease.
The surface is maintained by brushing it with a soft, long-haired brush or by using the vacuum
cleaner with a brush. The stove can also be dusted with a duster. Always remember: only when
the stove is cold.
Jointings can look okay, but they collapse under the heat and thereby lose the ability to keep the
stove sealed. Jointings should be changed as needed as it is important to good combustion and a
clean window that the stove is sealed.
The insulation plates in the combustion chamber that are broken or worn can easily be changed
as they are loosely fixed. The material used is called Vermiculite and is a porous, but very suitable
insulation material. It has no effect on the stove's efficiency that the insulation cracks. However, it
should be changed when the wear surpasses half of the original thickness.
Painting the stove with Senotherm-spray can cover spots or small scratches from kettles and
such. Larger damages needs to be ground with fine steel wool, vacuumed and then sprayed.
The can has to be shaken vigorously and then sprayed on at a distance of 15-20 cm. It is very
important that the stove is not in use and completely cold before you use the spray due to the fire
hazard. In order to keep the stove's varnished surfaces looking nice for years to come you should
try to avoid touching the varnished surfaces when the stove is hot. Make sure to have sufficient
ventilation when using spray paint.
Glass normally does not need any maintenance apart from cleaning. This is most easily done
by using TermaTech's glass cleaner. Remember only to use glass cleaner when the stove is cold.
Glass is made of ceramic glass, be sure of environmentally disposal.
28
Original parts which need to be changed due to wear can be found at your dealer. Because of fit
etc. only original parts from TermaTech should be used.
Right to claim compensation for defective product is under current law. When stating
deviations the use of the product must be suspended immediately and the dealer must be con-
tacted.
Chimney/Flues Must be swept on regular occasions, as per manufacturers recommendations.
5 YEAR WARRANTY* / RIGHT TO INVOKE LACK OF CONFORMITY
If defects/faults are ascertained, use of the wood burner must be stopped immediately and the
dealer contacted.
*5 Year warranty
Provided that there has been normal operation of the wood burner, TermaTech offers a 5 year
warranty on material and manufacturing faults on the load-bearing frame, exclusive of the com-
bustion chamber.
Combustion chamber: The following parts are not covered by the warranty: The combustion
chamber, Cast iron parts (bottom, door and grate), Insulation material (vermiculite plates),
Smoke deflector plates, Glass, gaskets as well as the closing mechanism/handle.
Exterior parts: The following parts are not covered by the warranty: Varnished plates/surfaces,
stone facings, glazed tiles, concrete and glass as well as the closing mechanism/ handle
The warranty does not cover faults which are due to:
the user/mounting guide not being followed
the mounting being carried out incorrectly
overheating/deterioration of the materials, caused by the use of, for example, the incorrect
type of fuel, petroleum coke or too much fuel
the product has been connected to a chimney with poor drawing qualities, for example, chim-
neys that are too short or are leaking
the product being positioned or has been positioned/kept in unheated or damp surroundings
the product being in bad repair or not maintained in accordance with the instructions
normal wear and tear of wearing parts/expendable items as well as the varnish
similar circumstances which are not due to material or manufacturing faults
The lesser defects below, which cannot underlie any claim, can occur in the product:
naturally occurring variations in the colour nuances and marbling on the soapstone, sandsto-
ne and other stone cladding.
sounds which occur during burning are normal, this occurs when metal expands/retracts.
If a fault occurs during delivery to the customer, or if such a fault arises during the warranty pe-
riod which is covered by this warranty, TermaTech A/S agrees to send a suitable replacement part
free of charge to rectify the fault. Any additional obligation of TermaTech A/S to remedy the fault,
for example, in the form of installation of the replacement part, does not exist.
In addition the purchaser has, apart from the right to a replacement part, no right to either direct
or indirect damages.
Repairs of faults or replacement of parts on the product do not extend the product or replacement
part's warranty period. Neither does a new warranty period begin for the product or replaced part.
Apart from the above warranty rules, the consumer also has those rights which are evident from
the obligatory consumer legislation
Any fault or defect must be examined by the vendor who has sold the product. In this case the
purchaser must be able to prove that the product has been purchased via the vendor and when
it was purchased, for example, in the form of an invoice/receipt. The purchaser must specify the
model and production number, which is stated on the product. If the purchaser wishes to refer to
a fault, the vendor must be informed within a reasonable time, i.e. 14 days after the defect has
been ascertained.
HINTS
Lighting after long break
If the stove has not been used for a long time the chimney should be checked for possible block-
age before lighting. Furthermore it is a good idea to remove any dust from the wood-burning
stove as it might smell after a long break.