Herunterladen Inhalt Inhalt Diese Seite drucken

VEGA VEGAWAVE S 61 Betriebsanleitung Seite 22

Vorschau ausblenden Andere Handbücher für VEGAWAVE S 61:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8 Supplement
Transistor output
Ʋ Switching voltage
Ʋ Switching current
Ʋ Blocking current
Modes (switchable)
Switching delay
Ambient conditions
Ambient temperature
Storage and transport temperature
Process conditions
Process pressure
Process temperature
Density
Granular size
Electromechanical data
Options of the cable entry
Ʋ Cable entry
Ʋ Cable gland
Ʋ Blind plug
Spring-loaded terminals
Adjustment elements
Mode switch
Ʋ Min.
Ʋ Max.
Voltage supply
Relay output
Ʋ Operating voltage
Ʋ Power consumption
Transistor output
Ʋ Operating voltage
Ʋ Power consumption
Electrical protective measures
Protection rating
Altitude above sea level
22
Floating transistor output
max. 55 V DC
max. 400 mA
< 100 µA
min./max.
on: approx. 0.5 s
off: approx. 1 s
-40 ... +70 °C (-40 ... +158 °F)
-40 ... +80 °C (-40 ... +176 °F)
-1 ... 25 bar/-100 ... 2500 kPa
-50 ... +150 °C
> 0.1 g/cm³
max. 10 mm (0.4 in)
M20 x 1.5
M20 x 1.5
M20 x 1.5
for wire cross-section up to 1.5 mm² (AWG 16)
Min. detection or dry run protection
Max. detection or overflow protection
20 ... 253 V AC, 50/60 Hz, 20 ... 72 V DC (at
U >60 V DC, the ambient temperature can be max.
50 °C/122 °F)
1 ... 8 VA (AC), approximately 1.3 W (DC)
10 ... 55 V DC
max. 0.5 W
IP66/IP67 acc. to IEC 60529, Type 4X acc. to NEMA
up to 5000 m (16404 ft)
VEGAWAVE S 61 •