GENERAL FEATURES

The V250 valve can be used for the following applications:
a) simplex, duplex or multiplex softening (decalcification) systems, for domestic,
laboratory and industrial use.
b) simplex or duplex demineralisation and dealkalisation systems for laboratory and
industrial use and all other applications requiring high quality water.
c) Simplex or duplex filtration depending on required the backwash flow rate for
domestic, labs or industrial usage.
The valves are constructed with materials that ensure maximum strength and quality.
The valves use a wide range of controllers for the management of all service and
regeneration operating phases. In the various models, these devices allow programming,
with time, volume, volumetric delayed and conductivity reading in microsiemens/cm, of
all operational phases for water treatment systems that fall within one of the types
indicated above.

TECHNICAL SPECIFICATIONS

Operating pressure
Service flow rate
Backwash flow rate
Slow rinse flow rate
Fast rinse flow rate
Static pressure resistance
Maximum quantity of regeneration resin
Operating temperature
Basic material of primary components
Inlet/Outlet coupling
MANUAL_V250.indd 17
V 2 5 0
from 1.5 to 6 bar
3
21 m
/h
12 m
3
/h
From 300 to 1000 l/h
14 m
3
/h
22 bar
500 liters
From 5 to 40 °C
ABS + fv
2" ¼ BSP male
15