Herunterladen Inhalt Inhalt Diese Seite drucken

Interlogix VE1120-D Serie Installationsanleitung Seite 3

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7
(1)
VE1120-D
J4
J3
CP
Normal
A
larm
(2)
VE1120-D
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
EN: Installation Sheet
Introduction
The VE1100-D series includes the VE1120-D PIR and
VE1120AM-D PIR-AM motion sensors. They have a patented
mirror, pyro, and signal processing technology.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Animals within the detector field of view
Obscuring the detector field of view with large objects,
such as furniture
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)
P/N 146626999-1 (ML) • REV D • ISS 06MAY19
< 33 Ω
J4
J3
J4
J3
J4
J3
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
VE1120AM-D
J4
J3
CP
< 33 Ω
Normal
A
larm
VE1120AM-D
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
AM/TF
Installing the detector
Figure 7
(1) Standard connection (factory
default)
(2) Dual loop connection
CP Control panel
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, steps 2 and 3).
3.
Fix the base to the wall. For flat mounting use a minimum
of two screws (DIN 7998) in positions A. For corner-
mounting use screws in positions B or C (Figure 3). To
install a pry-off tamper, use position A or C.
4.
Wire the detector (see Figures 3 and 7).
5.
Select the desired jumper and DIP switch settings (see
Figure 5). See "Jumper settings" on page 4 for more
information.
6.
Remove the blinders and add the stickers, if required (see
Figure 6 for an example).
For ceiling-mount applications that require a 90° coverage
7.
use the SB01 swivel-mount bracket.
J4
J3
J4
J3
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
AM/TF
WT Walk test
AM Antimasking
D/N Day/night
Rtest
Remote test