Connect the Breakout Cable (Optional)
CAUTION:
A ferrite is included with the vision system standard components.
To reduce emissions, the ferrite must be attached to the Breakout cable.
Note:
I/O wiring or adjustments to I/O devices should be performed when
l
the vision system is not receiving power.
The Ethernet cable should be unplugged or the PoE source powered
l
down before making adjustments to the connections at the far end of
the Breakout cable.
Unused bare wires can be clipped short or tied back using a tie made
l
of non-conductive material.
1. Verify that the vision system's power supply is unplugged and not receiving
power.
2. Attach the ferrite around the Breakout cable, adjacent to the strain relief on
the cable.
3. Connect the Breakout cable's M8 connector to the vision system's I/O
connector.
4. Connect the trigger and high-speed I/O wires to an appropriate device (for
example, a PLC, trigger sensor or strobe light).
7