Set-up and installation
3.5

Installing optional accessories

3.5.1
Installation of electric backup heater
(EKBUxx)
INFORMATION
If the ceiling height is low, the storage tank must be tilted to
install the backup heater when empty. This must be done
before any further installation steps.
The indoor unit provides the option of installing an electrical auxiliary
heater (backup heater EKBUxx). For example, renewable energy
can be used as an additional heat source.
INFORMATION
A separate manual containing instructions about installa-
tion and operation is included with this component.
3.5.2
Installation of the external heat generator
connection set
The connection set for external heat generators must be installed to
control an electrical backup heater or another external heat gener-
ator.
1
Open the housing by removing the screw.
2
Remove additional components from the housing (strain relief
clip, cable tie, grommet).
3
Attach the connection set to the controller housing of the indoor
unit. To do this, insert the hooks (1) of the connection set into
the slots of the controller housing (2); then press the connection
set downwards.
Fig. 3-25
Fitting the connection set
4
Attach the grommet (3) to the bushing between the connection
set (A) and the controller housing (B).
5
Attach the fastening rivet (4).
Fig. 3-26
Cable gland
6
Guide the cable of the Ultra EHS PCB through the cable grom-
met and connect it to the RoCon BM2C (see
Installer reference guide
18
7
After the installation and the electrical connections (see
Chap. 3.6
and close it with the screw.
3.5.3
The optional DB connection kit allows better access for connecting
the DrainBack pipe (solar feed).
Fig. 3-27
3.5.4
The optional P connection kit for Biv device types allows better ac-
cess for connecting the inflow and return flow lines of a pressurised
solar system or another external heat generator on the storage tank.
The kit contains two thermally insulated corrugated pipes that are
connected to the connections of the storage tank via a union nut. At
the other end of the corrugated pipes there is an adapter for different
connection sizes of the supply and return pipes.
Fig. 3-28
Fig.
3-41).
or
Chap.
3.7) have been completed, replace the cover

Installation of the DB connection kit

DB connection kit
A
DB pipe connection (solar inflow)
B
FlowSensor (not part of the DB connection kit, but included
with EKSRPS4)
C
Flow rate limiter (FlowGuard)
D
Solar inflow connection
on the storage tank

Installation of the P connection kit

P connection kit for Biv device types
A
Connection for inflow (red)
B
Connection for return flow (blue)
Daikin Altherma ETS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1447299_00 – 06/2019 – EN