REPLACING THE DIAPHRAGM

The diaphragm of your pool cleaner operates at the rate of approximately 360 beats per minute.
If your pool cleaner operates daily for 8 hours, the diaphragm will open and close over 60 million
times in a year! The design has been perfected over many years and, properly cared for, the diap-
hragm will last for several seasons. In the event that it does become worn or damaged and needs
to be replaced, simply follow these easy steps:
1.
Unscrew the HANDNUT and remove it, together with the OUTER EXTENSION PIPE and the THRUST WAS-
HER. Place these items to one side.
2.
Hold the INNER EXTENSION PIPE (IEP) and gently pull it towards you. This pulls the tabs out of their recess
3.
Turn the INNER EXTENSION PIPE so the tabs line up with the holes in the IEP LOCATOR. Do not remove
the INNER EXTENSION PIPE from the BODY
50
MV-1639-11-2017 . © All rights reserved Swim & Fun Scandinavia ApS