3.
Dispense the cement directly onto the internal surface of the veneer. Place the veneer gently onto the tooth,
allowing the cement to slowly flow from all margins.
4.
Spot cure the veneer into place on the facial surface, away from the margins, using a small diameter light guide
for 10 seconds.
5.
After removing the excess cement, light cure all surfaces using a Demi Ultra curing light for 10 seconds.**
Additional Notes
†or OptiBond S
††or OptiBond Versa
Note: Maxcem Elite Chroma minimum working time is
time is less than 4 minutes at oral temperature.  These times may vary based on storage conditions,
temperature, humidity, and age of the product.
** Recommended Curing Times: 
1 minute 20 seconds
at room temperature; Set
Demi Ultra, Demi Plus/Demi, and L.E.Demetron II: 10 seconds.
L.E.Demetron I & Optilux 501: 20 seconds. 
For all other lights, see manufacturer's recommendations.
STORAGE:  Store the product within a temperature range of
optimum freshness, store product in a refrigerator.
Keep product in foil package until initial use. Once the foil pouch is opened, use within 6 months and prior to
expiration date printed on syringe label.
6
4°C (39°F) to 25°C
(77°F).  Avoid excess heat.  For
Allow the product to reach room temperature prior to use.