DDL IN (XPD2)
DDL OUT (XPD1)
DDL mode S2
DDL address S1
DDL LEDs
Display of valve status
12/14 with LEDs
Fig. 1:
LEDs and switches
3

DDL addresses

The DDL address is set with the S1 switch. The
guidelines for setting the address can be found in
the DDL system specifications.

3.1 DDL mode

The DDL baud rate is set with the S2 switch. All
participants must be set to the same baud rate.
Table 1:
DDL baud rate
Bit
Open
1
DDL 125 kBaud
2

No function

AVENTICS | VS LP04 DDL | R402000483-BDL-001-AD
Valve 1
Port 1 compressed
air supply
Ports 2+4, working lines
On
DDL 250 kBaud
(default)
No function
3.2 No function
The output data length is determined by the
hardware. The data length is set according to the
degree of expansion of the valve terminal system. A
valve terminal with 4 positions requires 1 byte, 8
positions 2 bytes, 12 positions 3 bytes, and a valve
terminal with 16 positions requires 4 bytes.
Switches cannot change position while the
device is running. Changes to switch positions
are only accepted after the device has been
switched off and on again.
3.3 Output data range in the pilot
control
The DDL address sets the position of the output data
in the data section of the DDL bus module and thus
sets the position in the address section of the pilot
control.
CAUTION
13