DC voltage
Range
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
600 V overload protection; Impedance: ≥10 MΩ
Permitted display with short-circuited measuring input: ≤5 Counts
*Accuracy: 5 - 100% of the measuring range
Resistance
Range
400.0 Ω
4.000 kΩ
40.00 KΩ
400.0 KΩ
4.000 MΩ
40.00 MΩ
Overload protection 600 V; Measuring voltage: approx. 0.5 V
*Accuracy: 5 - 100% of the measuring range; <400 Ω with zero adjustment (REL function)
Capacitance
Range
400.0 nF
4.000 µF
40.00 µF
100.0 µF
600 V overload protection
Permitted display with open measuring input: ≤5 Counts
*Accuracy: 5 - 100% of the measuring range; ≤1 µF with zero adjustment (REL function)
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 Ω
0.001 KΩ
0.01 KΩ
0.1 KΩ
0.001 MΩ
0.01 MΩ
Resolution
0.1 nF
0.001 µF
0.01 µF
0.1 µF
Accuracy*
±(0.8% + 8)
±(1.2% + 5)
±(1.5% + 5)
Accuracy*
±(1.2% + 5)
±(1.0% + 5)
±(1.2% + 5)
±(2.0% + 5)
Accuracy*
±(3.0% + 5)
±(5.0% + 10)