Technical Data - Lelit PS25SP Bedienungsanleitung

Dampferzeuger 2,5 lt mit dampfbürste
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
COMPONENTS:
1.
Safety cap
2.
Boiler switch
3.
Iron switch
4.
Low water indicator light
5.
Steam button
USER INSTRUCTIONS:
1.
Remove the ironing machine from its packing and make sure all packing parts have been taken off
(including the protection bags). Lay the machine on a flat and steady surface fitted to support it next to a
wall socket (max. mt. 1,5).
2.
Unscrew the safety cap (1) and let the internal air out. Fill the boiler with max. 2,0 litres of water, use
the funnel supplied, making sure you do not overfill the tank. Close the safety cap (1).
3.
Insert the plug into an electrical outlet; switch on the boiler (2) and iron switch (3). The red pilot light of
the two switches will go on, confirming that the switches are on.
4.
Wait that the boiler switch's red light (2) goes off (it takes about 10 minutes). While ironing, the boiler
switch's red light (2) normally comes on.
5.
The machine is ready for use.
6.
Press the steam button (5).
7.
In case the steam stops during ironing and the low water light indicator (4) comes on, it means that
there is not enough water in the tank. To start ironing again, switch off the boiler switch (2); press the
steam brush button (5) to ensure there is no more steam in the boiler, slowly open the safety cap (1),
disconnect the plug and refill to the required level. Fill the boiler with warm water and wait for it to build
up pressure again.
8.
When you first press the steam button (after having turned the boiler on and depressed the steam
button on the iron) you might notice a decrease in pressure. This is because the tank has air in it. In
order to have plenty of steam (after you have depressed the iron) wait until the pressure goes back up to
the maximum level before you begin.
CAUTION:
Do not leave the machine unattended while the plug is connected to the socket.
-
For complete safety, before filling the boiler, please disconnect the plug.
-
While using the machine, never unscrew or remove the cap (1) while under pressure. Before removing it,
-
make sure that it does not give off steam anymore by shutting the boiler off, and pressing the steam
brush button (5) to release all remaining steam.
The machine has a special heating element. Only qualified technician should replace it.
-
The safety cap (1) must be replaced with original parts only.
-
PLEASE NOTE:
The use of normal tap water is recommended. In order to clean the boiler and remove limestone, rinse it
internally (every 15-20 litres of water used or every month) only with tap water.

TECHNICAL DATA:

Adjustable iron thermostat set from 60°C to 215°C
Bimetallic safety iron thermostat with manual reset at 275°C
Brush heating element: 500W
Boiler power: 1000W (Version 230V: 50Hz / Version 120V: 60Hz)
Working pressure: 2,5 bar
Max. pressure: 5,5 bar
Tank nominal capacity: 2,5 litres