9.

TROUBLESHOOTING TABLE

This table facilitates identification of the cause of the defect. Users are encouraged to contact technical service without delay to
obtain instructions on how to repair and/or adjust the equipment safely.
RAVAGLIOLI S.p.A. shall not be liable for injury to people or animals or damage to property in the event the equipment is serviced,
repaired, maintained or operated by unauthorised persons and/or unqualified personnel.
PROBLEMS
ON button of play
tester pressed but
nothing happens
Play tester does not
work (light lit)
With the play tester off,
the light does not come
on when the play tester
operation button is
pressed
Play tester operation
button pressed, but the
plates do not move
correctly
When the OFF button
is pressed, the play
tester or light do not
go off
R200 - R200I
CAUSES
a)
Main switch in position 0 .
b)
Fuse for transformer or main safety
fuses broken.
c)
Electrical system, failure.
d)
Electronic card, failure.
Keyboar, failure.
e)
Electronic card, failure.
a)
Solenoid valve blocked in closing
b)
position.
c)
Pump suction filter blocked.
a)
Main switch in position 0 .
Fuse for transformer or main safety
b)
fuses broken.
c)
Electrical system, failure.
d)
Electronic card, failure.
e)
Keyboar, failure..
Bulb broken.
f)
a)
Keyboar, failure.
Electronic card, failure.
b)
Calibration valve not working properly.
c)
d)
Worn or damaged pump.
Pump suction filter partially blocked.
e)
Solenoid valve blocked.
f)
a)
Keyboar, failure.
Electronic card, failure.
b)
Versione n.0 (09/95) Rev. n.3 (04/00)
REMEDIES
a)
Turn switch to 1
b)
Replace broken fuses. If a fuse breaks
again, identify the causes of the
breakage.
c)
Check that connections and
components are working properly.
d)
Replace electronic card.
Replace keyboard.
e)
Replace electronic card.
a)
Reset solenoid valve.
b)
c)
Clean filter.
a)
Turn switch to 1 .
Replace broken fuses. If a fuse breaks
b)
again, identify the causes of the
breakage.
c)
Check that connections and
components are working properly.
Replace electronic card.
d)
e)
Replace keyboard.
f)
Replace bulb.
a)
Replace keyboard.
Replace electronic card.
b)
Ask dealer for technical assistance.
c)
d)
Check that the pump is working
properly and replace if necessary.
Clean the filter.
e)
Reset solenoid valve.
f)
a)
Replace keyboard.
Replace electronic card.
b)
33