1.1. Combination

The indoor units can be installed in the following range.
Always use appropriate indoor units compatible with R-410A.
To learn which models of indoor units are compatible with
R-410A, refer to the product catalogs.
Total capacity/quantity of indoor units
Outdoor unit
U-8ME3
(*)
U-10ME3
(*)
U-12ME3
(*)
U-14ME3
(*)
U-16ME3
(*)
U-18ME3
U-20ME3
U-22ME3
U-24ME3
U-26ME3
U-28ME3
U-30ME3
U-32ME3
U-34ME3
U-36ME3
U-38ME3
U-40ME3
U-42ME3
U-44ME3
U-46ME3
U-48ME3
(*) = main units

1.2. Standard supplied accessories

Suction gas line piping (1)
1
Suction gas line piping (2)
1
Suction gas line piping (3)
1
Discharge gas line
1
piping (1)
Discharge gas line piping (2) 1
Discharge gas line piping (3) 1
Installation manual
1
Operation manual
1
Additional refrigerant charge
1
label
Refer to figure 15.
1
Installation and operational manual
2
Accessory pipes
U-8~16ME3XPQ
Urban Multi air conditioner
4PW16786-1C
Total capacity of
Total quantity of
indoor units
indoor units
100
~
260
13
125
~
325
16
150
~
390
19
175
~
455
20
200
~
520
20
225
~
585
20
250
~
650
20
275
~
715
22
300
~
780
32
325
~
845
32
350
~
910
32
375
~
975
32
400
~
1040
32
425
~
1105
34
450
~
1170
36
475
~
1235
38
500
~
1300
40
525
~
1365
40
550
~
1430
40
575
~
1495
40
600
~
1560
40
U-8ME3
U-10+12ME3
U-14+16ME3

1.3. Optional accessories

To install the above outdoor units, the following optional parts are
also required.
Refrigerant branching kit (for R-410A only: Always use an
appropriate kit dedicated for your system.)
For 3 pipes:
Refnet header
CZ-P29HK32Q
CZ-P64HK32Q
CZ-P75HK32Q
For 2 pipes:
Refnet header
CZ-P29HK12Q
CZ-P64HK12Q
Outdoor unit multi connection piping kit (For R-410A only:
Always use an appropriate kit dedicated for your system.)
Number of outdoor units connected
2
CZ-32PJ3PQ
To select an optimum refrigerant branching kit, refer to "6. Refrigerant
piping" on page 4.
1.4. Technical and electrical specifications
Refer to the Engineering Data Book for the complete list of
specifications.
2. M
AIN COMPONENTS
For main components and function of the main components, refer to
the Engineering Data Book.
3. S
ELECTION OF LOCATION
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures.
Make sure to provide for adequate measures in order
to prevent that the outdoor unit be used as a shelter
by small animals.
Small animals making contact with electrical parts can
cause malfunctions, smoke or fire. Please instruct the
customer to keep the area around the unit clean.
The inverter units should be installed in a location that meets the
following requirements:
1
The foundation is strong enough to support the weight of the unit
and the floor is flat to prevent vibration and noise generation.
2
The space around the unit is adequate for servicing and the
minimum space for air inlet and air outlet is available. (Refer to
figure 1 and choose one of the possibilities).
In case of an installation site where only the sides A+B have
obstacles, the wall heights have no influence on any indicated
service space dimensions.
A B C D
Sides along the installation site with obstacles
Suction side
Refnet joint
CZ-P20BK32Q
CZ-P29BK32Q
CZ-P64BK32Q
CZ-P75BK32Q
Refnet joint
CZ-P20BK12Q
CZ-P29BK12Q
CZ-P64BK12Q
3
CZ-48PJ3PQ
Installation manual