Herunterladen Inhalt Inhalt Diese Seite drucken

Lighting The Fire; Adding Fuel / Heating At Nominal; Thermal Output - HASE Lima Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Lima:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
8.

Lighting the Fire

The firing up phase should be as short as possible,
since higher emissions can occur during this phase.
The slider settings described in Table 1 are recom-
mendations that were determined under conform-
ance testing conditions, in compliance with the
relevant standard. Depending on the weather con-
ditions and the draught capability of your chimney,
accordingly adjust the slider positions for your Lima,
Sila or Sila Plus to the local conditions.
NOTE!
The Lima, Sila or Sila Plus may only be
operated when the fire box door is closed;
the fire box door may only be opened to
add fuel.
WARNING!
Never use spirits, petrol, or other flamma-
ble fluids to light the stove.
CAUTION!
The door handle can become hot dur-
ing operation. When adding more wood,
protect your hands with the oven gloves
included.
42
Lighting the Fire
Procedure
Position of Control
Elements
Switch air slider to the
Pull out the air slider out
heating-up position.
completely across the
red mark.
Pile up any remaining ash
and unburned charcoal
into the centre of the
Delhi
combustion chamber.
Open fire grate.
Pull fire grate slider all the
way out.
Place 4-6 small pieces of
wood with an approx. Ø of
3-6 cm and max. 2 kg in
the middle of the burning
chamber. Layer these
cross-wise on top of each
other. Place approx. 0.5 kg
of wood shavings on top
as a firelighter.
Light the kindling/ignition
material.
Stop the heating phase
Push in the air slider until
as soon as the fuel is
the red marker is no longer
completely ignited.
visible.
Close fire grate.
Push in fire grate slider.
Tab. 1
9.

Adding Fuel / Heating at Nominal

Thermal Output

More fuel should be added to the fire when the
flames from the previous burning off phase have just
gone out.
Adding Fuel / Heating at Nominal Output
Procedure
Position of
Control Elements
Adjust the combustion air.
Set air slider on position
between 2 and 3.
Close fire grate.
Push in fire grate slider.
Add two logs weighing
approx. 1.5 kg total, place
them with the ends facing
the front of fire box. Only
add one layer of fuel.
Tab. 2
CAUTION!
Please ensure that the logs are inserted
with sufficient distance (at least 5 cm)
from the furnace window.