Verfügbare Sprachen

  • DEUTSCH, seite 1
NOTICE
Protective Extra Low Voltage (PELV)!
The device is designed in accordance with protection class III for sup-
ply with PELV (Protective Extra-Low Voltage).
Pin assignment
3
PWR / SWIO, M12 connector, A-coded
Pin No.
Designation
1
VIN
2
GND
3
SWI1
4
SWO2
5
FE
6
n.c.
7
SWO5
8
SWO6
9
SWO7
10
SWO8
11
SWI3
12
SWI4
Thread
FE (functional earth)
(M12
connector)
NOTICE
The core colors only apply if Leuze electronic's original connection ca-
bles are used (see operating instructions, chapter "Cables acces-
sories").
Core color
Assignment
Brown
+18 ... +30 V DC operating voltage
Blue
Negative operating voltage (0 V DC)
White
Digital switching input 1
(trigger)
Green
Digital switching output 2
(READY)
Pink
Functional earth
Yellow
Not used
Black
Digital switching output (-X)
Gray
Digital switching output (+X)
Red
Digital switching output (-Y)
Violet
Digital switching output (+Y)
Gray/pink
Digital switching input 3
(program selection 0)
Red/blue
Digital switching input 4
(program selection 1)
Connection cable shield.
The shield of the connection cable is
on the thread of the M12 plug.
EN