Herunterladen Inhalt Inhalt Diese Seite drucken

Before The First Use - Vitek VT-1768 BK Betriebsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
ENGLISH
Do not leave children unattended. Do not allow chil-
dren to use the unit as a toy.
For children safety reasons do not leave polyethyl-
ene bags, used as a packaging, unattended.
Attention! Do not allow children to play with
polyethylene bags or packaging film. Danger of
suffocation!
Never pull the power cord when disconnecting the
unit from the mains; take the power plug and care-
fully pull it out of the socket.
Never use the unit if the power cord or the power
plug is damaged, if the unit works improperly or after
the unit was dropped.
Do not disassemble the unit by yourself, if any mal-
function is detected or after the unit was dropped,
apply to the nearest authorized service center.
Transport the unit in the original package only.
Keep the unit out of reach of children and disabled
persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USAGE
ONLY

BEFORE THE FIRST USE

After unit transportation or storage at low
temperature (in winter), it is necessary to keep it
for at least two hours at room temperature before
switching on.
Unpack the humidifier, remove any stickers and
package materials that can prevent unit operation.
Examine the unit for damages. In case of damages
do not switch the unit on.
Notes:
Use the humidifier at the room temperature from
+5° С to +40°С, and relative humidity less than
80%.
Water temperature should not exceed +40°С.
Before plugging the unit in, make sure that your
home mains voltage corresponds to unit operat-
ing voltage.
Usage of the unit
1. Remove the water tank (13) from the unit body.
2. Turn over the tank (13), unscrew the lid (14) with the
cartridge filter (12) rotating it counterclockwise.
3. Fill the tank (13) with necessary amount of water,
insert the lid with the cartridge filter (12) and screw it
in, rotating it clockwise.
4. Place the filled water tank (13) on the unit body. Wait
for some time, which is necessary to fill the process
chamber with water.
5. Insert the power plug into the mains socket, the
water tank illumination (16) will light up.
6. Switch the humidifier on by touching the touch but-
ton (1) « » or pressing the button (30) on the
remote control (19), the room temperature (27),
VT-1768.indd 4
the humidity level and the mist release intensity
icon (26) will appear on the display, the mist will be
released intensively from the lid nozzles (9). The
nozzles rotate 180° around the axis, which allows
sending the mist flow in any direction without mov-
ing the humidifier.
Notes:
Every
pressing
of
the
accompanied with a sound signal.
If no button is pressed on the control panel or on
the remote control within 30 seconds, the display
brightness will decrease automatically.
7. To switch the ionization mode on, touch the touch
button (3) « » or press the button (31) on the
remote control (19), the icon (23) will light up on
the display (7). To switch the ionization mode off,
touch the touch button (3) « » again, the icon (23)
will go out.
8. To switch the water heating mode on, touch the
touch button (6) « » or press the button (32) on the
remote control, the icon (25) will light up on the dis-
play (7). In this mode the water is preheated before it
is evaporated, which helps to disinfect the water and
facilitates its evaporation.
Note:
Switching this function on may slightly change the
room temperature (27) and humidity (21) indication
on the display (7). If the room humidity is less than
20%, the indicator (27) will show this value as «20»,
this is not a malfunction.
9. You can set the humidifier operation time using the
timer touch button (5) « » on the control panel or
by pressing the humidifier on/off button (30) on the
remote control (19) consequently, the icon «TIMER»
will be flashing on the display. Set the required
humidifier operation time from 1 to 12 hours, the time
will be shown with the digital indication (27) on the
display (7). In this mode the digital indicator (27) will
show the room air temperature and timer operation
time by turn with an interval of 30 seconds.
10. To set the mist release intensity, touch the touch but-
ton (4) «
» or press the button (28) on the remote
control; you can set the required intensity, which will
be shown as a changing mist release icon (26) on
the display (7).
11. To switch the automatic humidity maintenance mode
on, touch the touch button (2) « » or press the
button (29) on the remote control (19), the icon
«HUMID» will be flashing on the display; press the
button repeatedly to set the required humidity in the
room (from 45 to 90%, the setting step is 5%). When
the preset level is reached, the humidifier is switched
to the stand-by mode, if the humidity level decreases
within 10%, the unit will resume operation automati-
cally. In the automatic humidity maintenance mode,
the icon «HUMID» flashes on the display (7), the
4
control
buttons
is
20.01.2014 12:26:12

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis