Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
EBL12
Maintenance
Preventing ESD problems
The components inside the tool and controller are sensitive for electrostatic discharge. To avoid future malfunc-
tion, make sure to perform service and maintenance in an ESD approved work environment. See below figure
as an example of an acceptable work station for service.
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES
Service instructions
Overhaul and preventive maintenance is recommended at regular intervals once per year or after maximum
250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if used at high
torque, high cycle rate or long tightening times. If the machine is not working properly, it should immediately
be taken away for inspection.
At the overhauls, all parts should be cleaned accurately and defective or worn parts (i.e. O-rings) should be
replaced.
Cleaning/Inspection
Clean all parts thoroughly in white spirit or similar cleaning agent. After the cleaning, inspect all parts. Damaged
and worn parts should be replaced.
Overhaul
No regular overhaul is needed, except for complementory lubrication of gears.
Lubrication
Lubrication
The planetary gears are lubricated with grease of type Molykote Longterm 00. If needed, a complementary
lubrication (see fig.) of grease could be made, maximum 0.2 cm
No further regular lubrication is required.
Repair
EN
ESD carpet
wrist strap
© Atlas Copco Industrial Technique AB - 9836 8184 00
3
.

Service

9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis