Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Electrical Connection - Beko HISW 63222 SO Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55
3
Installation
Total gas con-sump-
tion (kW)
0-2
2-3
3-4
4-6
6-8
8-10
10-11.5
11.5-13
13-15.5
15.5-17
17-19
19-24
3.2.2 Rooms that do not have openable
doors and/or windows that open di-
rectly to the outer environment
If the room where the appliance is installed does
not have a door and/or a window that opens di-
rectly to the outer environment, other products
shall be sought that definitely provide a fixed non-
adjustable and non-closable ventilation opening
which meets the total minimum ventilation open-
ing requirements for the total gas consumption of
the appliance as indicated in the above table.Also
the appropriate building regulations advise should
be followed. Where a room or internal space con-
tains more than one gas appliance, additional
ventilation area shall be provided on top of the
requirement given in the table above. Size of addi-
tional ventilation area shall be appropriate to reg-
ulations of other gas appliances. There should also
be a minimum clearance of 10mm on the bottom
edge of the door that opens to the inner environ-
ment in the room where the appliance is installed.
You must ensure that items such as carpets and
other floorcoverings etc., do not affect the clear-
ance when the door is closed.
14 / EN
min. Ventilation
opening (cm²)
100
120
175
300
400
500
600
700
800
900
1000
1250
The cooker may be located in a kitchen, kitchen/
diner or a bed-sitting room, but not in a room con-
taining a bath or a shower. The cooker must not be
installed in a bed-siting room of less than 20m3.
Do not install this appliance in a room below
ground level unless it is open to ground level on at
least one side.

3.2.3 Installation and connection

The product must be installed in accordance with
all local gas and electrical regulations.

3.3 Electrical connection

Connect the product to a grounded outlet/line
protec-ted by a fuse of suitable capacity as stat-
ed in the "Technical specifications" table. Have the
grounding installation made by a qualified elec-
trician while using the product with or without a
transformer.
The Manufacturer shall not be liable for any dam-
ages that will arise due to using the product with-
out a grounding installation in accordance with the
local regulations.
WARNING: The product must be
connected to the mains supply only
by an authorised and qualified per-
A
son. The product's warranty period
starts only after correct installation.
Manufacturer shall not be held re-
sponsible for damages arising from
procedures carried out by unauthor-
ised persons.
WARNING:
ble must not be clamped, bent or
trapped or come into contact with
A
hot parts of the product.
A damaged power cable must be
replaced by a qualified electrician.
Otherwise, there is risk of electric
shock, short circuit or fire!
Built-In Hob / User Manual
The power ca-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis