Starting ON the tool
GREEN
GREEN
Stopping OFF of the tool
RED
RED
Battery charge level
-
-
-
-
-
-
Battery protection CUT-OFF
-
-
Temperature protection
YELLOW
YELLOW
ORANGE
ORANGE
Tool security
-
RED
Maintenance indication
-
ORANGE
Maintenance indication
-
ORANGE
Return for maintenance
-
RED
Tool connected to USB
-
BLUE
0512 - BCP055G - KW Hydraulik GmbH – Köppelsdorfer Str. 132 – D-96515 Sonneberg – www.kw-hydraulik.de - Seite 14
Press the button ON/OFF tool.
The 3 LED lighting GREEN for 1 second.
The tool is ready for work.
GREEN
Press the button ON/OFF tool.
The 3 LED lighting RED for 1 second. The tool switches OFF.
The tool switches OFF automatically without use during 10min.
RED
After powering ON the tool, if the LED battery is lighting GREEN, the battery is full
charged.
GREEN
After powering ON the tool, if the LED battery is lighting ORANGE, the battery is half
charged.
ORANGE
After powering ON the tool, if the LED battery is lighting RED, the battery is discharged.
The battery must be recharged. Replace the battery by a full charged battery.
RED
If the battery is not powerful enough for one cycle, the tool is automatically locked. The
LED battery flashing RED.
The battery must be recharged. Replace the battery by a full charged battery.
RED
If the temperature is out of range of use, the cycle and maintenance LED flashing
YELLOW and ORANGE. The tool can't be used.
-
For user security, the tool is blocked automatically in case of problem. The LED
maintenance flashing RED during 10 seconds.
Press the button ON/OFF tool.
-
If the indication reappears, return the tool to the DUBUIS after-sales Service.
The LED maintenance lighting ORANGE all the time after ON to indicate the future
maintenance.
The user has 1000 cycles before the final block of the tool.
-
Return the tool to the DUBUIS after-sales Service.
The LED maintenance flashing ORANGE all the time after ON. The tool is automatical-
ly locked after each crimping.
Press the button ON/OFF tool.
-
The user has 500 cycles before the final block of the tool.
Return the tool to the DUBUIS after-sales Service.
The LED maintenance flashing RED. The tool is definitively locked.
Return the tool to the DUBUIS after-sales Service.
-
When the tool is connected to the USB port, the LED maintenance lighting BLUE dur-
ing the connection.
-

LED INDICATIONS