With the RS 232/422/485 connected, a bi-directional
communication is established by selecting HOST. Data are
sent to an external computer every time the external
computer asks for the values.
The data available are:
Speed adjust
Pump/controller operating condition
Cycle time
Pump life
Pump temperature
Pump current
Pump voltage
Controller output frequency
Cycle number
R1 condition
R2 condition
Life time and cycle # zeroing
Configuration parameter readings
Configuration parameter setting
Note that the new input value are put in effect only at the
next STOP/START of the pump.
If PRINT is selected and a printer is connected on RS
232/422
line,
an
unidirectional
established and every minute the data are sent to the
printer, even if the pump is not running.
The set of data available are:
Pump speed KRPM
Pump temperature
Pump current A
Pump power W
R1 condition
R2 condition
The controller is factory-set to HOST.
communication
is
67
TECHNICAL INFORMATION
Confirm the selection by pressing the PUMP
CURRENT push-button.
In this way you enter into an operating phase named
"Monitor Relay Programming" described in the
following paragraph.

Monitor Relay Programming

The display shows:
S P E E D
T H R E S H O L D
S E L E C T
I O N : X X K R P M
where: XXKRPM = is the switch point of relay R1 at the
preset turbopump speed, adjustable from 00 to 99 KRPM.
The speed threshold will condition the R1 and R2
operation (see the following cycle diagram] and it is
factory-set to 57 KRPM. Press the CYCLE NUMBER push-
button to select the first number.
S P E E D
T H R E S H O L D
S E L E C T
I O N : X X K R P M