If underfloor heating is installed at the set-up
location, place the appliance on an insulation
plate made from solid material.
The use of energy depends on the appliance
location selected. The use of energy can in-
crease if the temperature is higher or lower
than the prescribed room temperature.

Setting up the appliance

1. Place the appliance upright on as flat and
as firm a base as possible.
2. To ensure adequate air circulation,
– maintain a minimum distance of 7.5 cm
to the rear wall;
– maintain a distance of at least 10 cm at
the sides;
– keep free an area of at least 30 cm
above the appliance;
– do not place any objects on the appli-
ance;
– do not place the appliance on carpeted
flooring.
Aligning the appliance
1. Check the position with a spirit level.
2. Level out any unevenness on the ground
using the two front screw feet (8).
– Close the doors.
– Tilt the appliance backwards slightly and
screw/unscrew the screw feet.
– Stand the appliance back up again and
check the alignment with a spirit level.
– Repeat the process until the appliance
is standing up vertically. The appliance
should not move when opening the
doors.
Cleaning before use
To remove the odour that comes with all new ap-
pliances, clean the appliance before using it (see
"Cleaning the fridge" and "Cleaning the freezer"
on page EN-28).
Connecting the appliance to
the power supply
WARNING
Risk of electric shock!
Touching live parts may result in severe
injury or death.
Do not operate or continue to oper-
ate the appliance if
it shows visible signs of damage,
e.g. the power cord is defective,
it starts smoking or there is a smell
of burning,
it makes unfamiliar noises.
In such cases, remove the mains plug
from the socket or unscrew/isolate
the fuse and contact our service de-
partment (see page EN-37).
Never connect to a timer or a sepa-
(8)
rate remote-controlled system for dis-
tance monitoring and control.
If the mains plug is no longer acces-
sible after installation, an all-pole dis-
connecting device complying with
overvoltage category III must be
connected to the house wiring with a
contact gap of at least 3 mm; this in-
cludes fuses, circuit breakers and con-
tactors.