8. CLEANING AND MAINTENANCE

8.1 Routine maintenance
The routine and preventive maintenance basically consists in the weekly cleaning of the stainless steel parts with lukewarm soapy
water, rinsing abundantly and drying thoroughly. The unit must only be cleaned after first disconnecting the power supply upstream
from the equipment.
Should lime scale form on the bottom of the basin, clean with a vinegar solution or special products before rinsing abundantly with
water and drying.
Warning:
Under no circumstances should you use abrasive or corrosive detergents and utensils such as steel wool, brushes or metal
scrapers.
Bleach, hydrochloric acid and other compounds containing chlorine will damage the stainless steel.
The coloured parts must be cleaned with silicone wax.
The floor under the unit must not be washed with corrosive substances that might generate vapours damaging the equipment.
During cleaning, do not wash the equipment with jets of water .
8.2 Non-routine maintenance
The non-routine maintenance must be performed by qualified personnel in the event of a fault or anomaly, wherever possible with
the equipment disconnected from the power mains.
In this case, repairs or replacements might be required. The faulty parts must only be replaced with materials and components identical
to the originals or specified by the Manufacturer.
The replacement of components or the modification of the equipment by the user without written permission from the Manufacturer, or
the use of non-authorized spare parts, shall instantly cause the warranty to be void.
8.3 Possible errors
If the BASIN does not heat, check the power supply and make sure the working thermostat is not at the minimum setting.
If the HEATED COMPARTMENT does not heat, check the power supply and make sure the working thermostat is not at the minimum
setting, or that the heated cabinet's vents are obstructed.
If, after performing the checks indicated, correct operation is still not achieved, switch off the equipment and contact the supplier
without delay.
9
SCRAPPING
At the end of its service life, the equipment must be disconnected from the power mains before disassembling the various components.
Special care must be taken to avoid the risk of accidents associated with the form and weight of each component.
The various parts (electrical components, rubber piping, fairlead linings etc.) must be sorted so as to make the best possible
contribution to the protection of the environment in compliance with the laws in force.
TECHNICAL DATA
Compartment type
Overall dimensions mm:
L = length
P = depth
H = height
Depth with tray slide mm
Compartment dimensions mm:
length
depth
height
Compartment capacity – litres
Door type
N° of doors
Number of basins
Basin dimensions mm:
length
depth
height
Basin capacity GN
Water inlet diameter
Water outlet diameter
Basin power kW
Compartment power kW
Total power kW
Supply voltage
Max. weight (Kg).
A010016 Rev. 5
PDF created with FinePrint pdfFactory Pro trial version
Table A:
TECHNICAL FEATURES OF BAIN-MARIE UNITS
BT 8
BT 12
BT 15
BT 23
(EGB 8)
(EGB 12)
(EGB 15)
(EGB 23)
OPEN
OPEN
OPEN
OPEN
800
1200
1500
2300
700
700
700
700
900
900
900
900
1000
1000
1000
1000
520
920
1220
1880
590
590
590
590
400
400
400
400
122
217
287
443
/
/
/
/
/
/
1
1
1
630
960
1280
1930
510
510
510
510
210
210
210
210
2 1/1
3 1/1
4 1/1
6 1/1
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
2.4
3,6
3,6
7,2
/
/
/
2,4
3,6
3,6
7,2
380V
380V
380V
230V 1N
3F+N
3F+N
3F+N
70
85
100
135
Pagina 7 di 23
BA 8
BA 12
BA 15
(EAB 8)
(EAB 12)
(EAB 15)
CABINET
CABINET
CABINET
800
1200
1500
700
700
700
900
900
900
1000
1000
1000
520
920
1220
590
590
590
400
400
400
122
217
287
/
Hinged
Sliding
Sliding
/
1
2
2
1
1
1
1
630
960
1280
510
510
510
210
210
210
2 1/1
3 1/1
4 1/1
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
2.4
3,6
3,6
/
/
/
/
2,4
3,6
3,6
380V
380V
230V 1N
3F+N
3F+N
85
108
115
http://www.fineprint.com
BA 23
BC 12
BC 15
BC 23
(EAB 23)
(ECB 12)
(ECB 15)
(ECB 23)
CABINET
HEATED
HEATED
HEATED
2300
1200
1500
2300
700
700
700
700
900
900
900
900
1000
1000
1000
1000
1880
920
1220
1880
590
590
590
590
400
400
400
400
443
217
287
443
Sliding
Sliding
Sliding
Sliding
2
2
2
1
1
1
1930
960
1280
1930
510
510
510
510
210
210
210
210
6 1/1
3 1/1
4 1/1
6 1/1
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
7,2
3,6
3,6
7,2
/
1,6
1,6
2,2
7,2
5,2
5,2
10,4
380V
380V
380V
380V
3F+N
3F+N
3F+N
3F+N
146
110
120
150