Usage parameters d0 to d11
Code
Condition
d0
IPM temperature
d1
Water temperature (inlet)
d2
Water temperature (outlet)
d3
Ambient temperature
d4
Frequency limitation code
d5
Pipe temperature
d6
Exhaust gas temperature
d7
Step of EEV
d8
Compressor working frequency
d9
Compressor current
d10
Fan Speed
d11
Error code for the last time
Remark: d4 Frequency limitation code, 0: No frequency limit; 1: Coil pipe temperature limit; 2: Overheating or overcooling
frequency limit; 4: Drive Current frequency limit; 8: Drive voltage frequency limit; 16:Drive high temperature frequency limit
Usage parameters P0 to P7
Code
Name
P0
Mandatory defrosting
P1
Work setting
P2
Timer on/off
P3
Water pump
P4
Current time
P5
Timer ON
P6
Timer off
P7
Inlet water temp. correction

Symbol description

102
Area of application
0-1
0-1
0-1
0-1
HH:MM
HH:MM
HH:MM
-9~9
Symbol for heat.
The light will be on when it is in operation. When defrosting, the light will
flash.
Symbol for cooling. The light will be on when it is in operation.
Symbol for automatic stop. The light will be on when it is in operation.
Symbol for automatic start, the light will be on when it is in operation.
MV-1225-1226-1298-11-2018 . © All rights reserved Swim & Fun Scandinavia ApS
Scope
0-120 °C
-9 °C ~ 99 °C
-9 °C ~ 99 °C
-30 °C ~ 70°C
0, 1, 2, 4, 8, 16
-30 °C ~ 70 °C
0 °C ~ C5 °C (125 °C)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error codes
Default
0
1
0
0
00:00
00:00
00:00
0
UK
Remark
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
N*5
Real testing value
Real testing value
Real testing value
Remark
0: Default normal operation
1: mandatory defrosting
1 Heating mode,
0 Cooling mode
1 Timer on/off is in opera-
tion, 0 Timer on/off does not
function (The setting of P4
and P5 will not work)
1 Always running, 0 De-
pends on the operation of
the compressor
0-23:0-59
0-23:0-59
0-23:0-59
Default setting: 0