be checked before putting the equipment into
operation (see 9.4).

7. Assembly and starting

Important!
You must fully assemble the appliance
before using it for the fi rst time!
You will require the following tools for assembly
and installation:
1 x open-ended wrench size 14 mm (not in-
cluded)
2 x open-ended wrench size 17 mm (not in-
cluded)
1 x open-ended wrench size 23 mm (not in-
cluded)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
7.2 Fitting the supporting feet (8)
Fit the supplied supporting feet as shown in
Figure 6.
7.3 Fitting the air fi lters (15)
Remove the transportation stopper (B) and screw
the air fi lters (15) securely to the equipment (Fig.
7, 8). Make sure that the intake opening on the air
fi lter faces down.
7.4 Changing the transportation cover (A)
Remove the transportation cover from the oil fi ller
opening (21) and insert the supplied oil sealing
plug (16) into the oil fi ller opening. (Fig. 9, 10.)
7.5 Mains connection
The compressor is equipped with a mains
cable with shock-proof plug. This can be
connected to any 230V ~ 50 Hz shock-proof
socket which is protected by a 13 A fuse.
Before you use the machine, make sure that
the mains voltage is the same as the operating
voltage (see the rating plate).
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
Anleitung_4010414_LB6.indb 12
Anleitung_4010414_LB6.indb 12
GB/IE
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossible.
7.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch
on the compressor. To switch off the compressor,
press the ON/OFF switch down.
7.7 Setting the pressure (Fig. 1-3)
Use the pressure regulator (3) to set the pres-
sure on the pressure gauge (5).
Pull the knob of the pressure regulator (3) in
order to release the pressure regulator.
Turn the pressure regulator knob to adjust the
pressure. When the required pressure setting is
reached, press the pressure regulator knob.
The set pressure can be drawn from the quick-
lock coupling (4).
The vessel pressure can be read off the pres-
sure gauge (14).
The vessel pressure is drawn from the quick-
lock coupling (20).
7.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7.9 Overload cut-out (Fig. 3)
The motor of this equipment is protected against
overload by an overload switch (G). If the rated
current is exceeded, the overload switch (G) will
shut down the equipment. After a short cooling
down period, the equipment can be switched on
again by pressing the overload switch (G).

8. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel to
avoid danger.
- 12 -