Herunterladen Inhalt Inhalt Diese Seite drucken

Pentair Fleck 4600 Bedienungsanleitung Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
4 - POWER HEAD
Metered
Time clock
Common settings
Time of day
Press the clutch on the 24 hour wheel, red gear, then turn the hour wheel to display the correct
hour in the window.
Salt volume per regeneration
Here is a table, usually used in water treatment.
Salt weight
n g / litre of resin
15
White dot
Set the capacity of soft water between 2 regenerations using the following
formula:
Water capacity in m
3
To do so, lift the transparent disc with the label and display the capacity
facing the white dot.
Example for the following drawing, the capacity set is 6.6 cubic meters
between two regenerations.
Pin pushed
outside
Use the same formula as for metered version and divide by daily water
consumption to obtain the number of days between 2 regenerations.
There are two time clock wheels:
- 7 days: based on the week, number 1 will refer to Monday, number 7 to
Sunday.
- 12 days: allows to set a regular interval every 2, 3, 4, or 6 days.
To set up, push the pins out.
Example: on the drawing one regeneration every 2 days.
Exchange capacity
in °tH / m
80
125
180
On the brine cam, there is a segment and a indication Label in Kilogram.
This segment with an indicator ensures the function of brine refill. Based
on the table, set the amount of salt in Kg necessary for the resin
regeneration. This way, the valve will send the correct volume of water
in the brine tank in order to dissolve the necessary volume of salt for
regeneration.
Example: 15 litres of resin x 125 g = 1875 g (1.9 kg of salt)
Place the indicator slightly under 2 kg.
= exchange capacity in m
Water hardness °tH
3
/ litre of resin
4
5
6
°tH – reserve capacity in m
3
Salt weight in g / °tH / m
20
25
30
4600 - 5600
3
E
N
G
L
I
S
H
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fleck 5600

Inhaltsverzeichnis