Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Guide; Precaution - Baxtran STA Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. TRoUBLESHooTING GUIDE

PROBLEM
No display when turn on the weighing
hook
Display flash
Can't turn on&off
Can't tare
Recharge indicator light can't turn on
Display isn't stable
The display don't show "0" when emp-
ty load
The error is large
Battery can't recharge
Remote distance shortened
10. ATTENTIoN
For good performance and precise measurement, be careful with daily operation and maintenance.
Rotate the load rather than the weighing hook if needed.
Do not use the weighing hook under thunder or rain.
Check the clips, pins and screws regularly.
When battery is out of power and battery indicator turns red, chech the battery or replace it with a full one.
Hang the weighing hook on special shelf in dry and well-ventilated room. Do not place the weighing hook on the ground
drectly.
34
REASON
Batterie damaged
Battery contacted loosed
Low battery
button damaged
buttond damaged
The recharger damaged
The recharger isn't plugged ready
The load is unstable
Load cell cable damaged
The weighing hook is damp environ-
ment for a long time
No enough time for heating the weighing
hook after turn on.
Put the weighing hook on ground for
too long time.
The weighing hook isn't hung properly.
Battery damaged.
Outlet damaged.
Receiver window is too dirty
Low battery of controller
USER'S GUIDE | WEIGHING HOOK | STA
SOLUTION
Check battery
Tighten the contact
Recharge the battery
Check & clean the button
Check & clean the button
Check the recharger
Insert plug again
Stabilize the load
Check and replace loadcell
Put the weighing hook in dry environ-
ment
After turning on, heating 3-5 minutes.
The hook should be hung.
Check the weighing hook and sling.
Replace battery
Replace the outlet
Check and clean.
Replace remote control battery.
EN