Where can the sunbed be installed?
Your Ergoline sunbed is intended for use in dry rooms that are not subject to water spray or dripping water. The humidity prevailing in
this room must not exceed 70 %. The temperature inside the room should not exceed the outside temperature by more than 3 to 4 °C
and be no greater than 35 °C in order to avoid too high a temperature at the bed surface.
Adequate ventilation and air extraction must be provided at all times.
Floor loads
The sunbed must be installed on a floor rated for a load-bearing capacity of 3.5 kN/m
< 3.5 kN/m
(350 kp/m
), the installer shall be required to furnish proof to DIN 1055 Sheet 3, June 1971.
2
2
Space required
Minimum floor space required for Ergoline Classic 450:
Width = 2370 mm
Depth = 2300 mm

Dimensions of Ergoline 450 ( in mm )

A = 1740
L
= 2400
B = 1530
M
= 2340
C =
300
N
= 1040
D =
25
O
= 2300
E = 1230
P
= 1130
F = 1150
Q
= 1180
G = 1570
R
=
517
H =
370
S
= 1700
K = 1250
The dimension "S" is valid for assembly of upper part.
. If the floor load-bearing capacity is
2
Assembling the sunbed
K
Fig. 25
H
D
Q
E
Fig. 26
2340
120
1440
900
19