Herunterladen Inhalt Inhalt Diese Seite drucken

Vimar RS10 Installations- Und Benutzerhandbuch Seite 29

Leiterplatte 230 vac mit display für schiebetorantrieb
Vorschau ausblenden Andere Handbücher für RS10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 66
RS10
- move the gate into the fully closed position (closing limit switch engaged, FCCH LED off)
- press the OK button to enter programming mode, the display will read APCH
- press and release the AP/CH button, the gate will open and the display will show OPEN
- press and release the AP/CH button to determine the starting point of deceleration on opening and the display will show the message SLO
- the gate continues slowing down until the opening limit switch trips (the FCAP LED goes out) and then automatically starts closing again, the
display shows the message CLOS
- press and release the AP/CH button to determine the starting point of deceleration on closing and the display will show the message SLO
- the gate continues slowing down until the closing limit switch trips (the FCCH LED goes out)
- the gate opens and the display shows OPEN
- press and release the AP/CH button to determine the pedestrian opening distance
- the gate continues until the closing limit switch trips (the FCCH LED goes out) the display reads END, the travel has been saved correctly.
7 . 4 P A R:
Used to modify all the parameters of the control unit, press the OK button to display the list of parameters, the display will show P01 (para-
meter number 1), the UP or DOWN button lets you scroll through the list of parameters (see parameter table).
x4
CLOSING
CHIUSURA
Press the pushbutton
until the parameter to
change
EN
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis