6 . 1 P rocedure f or f acilitated gate trav el programming:
Starting with the closing limit switch engaged (gate closed), after entering programming mode by pressing the UP, OK, and AP/CH button, the gate starts
opening at reduced speed until the opening limit switch is engaged. After 2 seconds the gate starts closing at cycle speed and slows down approximately
50cm from being completely closed and continues until the closing limit switch is engaged. The control panel saves the gate travel, with default decele-
ration speed and distances.
6 . 2 P rocedure f or sav ing a remote control associated w ith b utton A P / C H :
1
x2
P ress th e U P b utton 2 times, th e display w ill sh ow
1
Press the OK button, the display will show 1CH (indicating that the remote control button will be saved as APCH of the control panel) Press the OK button,
1
4 dots will appear on the display, indicating that the control panel is waiting for a remote control button to be tapped (timeout 10 seconds) After pressing
the remote control button the display will show a 4-digit number: the first digit indicates association (1 controls the APCH input 2 controls the pedestrian
entrance or the second channel output) the other 3 indicate the memory cell occupied by the remote control (the first remote control occupies cell 001,
the second one cell 002), the maximum capacity is 200 remote controls To save other remote controls repeat the procedure.
x4
N . B . : The first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with a fixed
x2
12-bit code
6 . 3 E x ample of th e procedure f or ch anging th e automatic closing time:
6
1
x4
6
24
1
1
The gate goes into the
fully open position and
1
slow speed
The gate goes into the
fully open position and
2
RA D
2
2
2
2
2
The gate closes at
Continues closing at
cycle speed
reduced speed until com-
2
slow speed
3
3
3
3
EN
3
3
3
pletely closed
4