Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic AW-RP50E Bedienungsanleitung Seite 39

Vorschau ausblenden Andere Handbücher für AW-RP50E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
Setup Software
 Displaying the "Setting" tab
 List box
The IP address of the AW-RP50 connected to the
network is displayed here.
The information of the network environment established
by the AW-RP50 selected here is displayed on the
"Setting" tab.
 Type
The units connected to the selected AW-RP50 are
displayed in this column.
CAMERA: Remote camera
SW:
Switcher
 Group
The numbers of the groups of cameras controlled by the
selected AW-RP50 are displayed in this column.
 CAMERA No
The numbers of the cameras controlled by the selected
AW-RP50 are displayed in this column.
 Type
The connection methods used for the units connected to
the selected AW-RP50 are displayed in this column.
Serial:
Serial connection
Network: IP connection
NoAsign: No setting (default setting)
The connection method can be changed manually.
Click
on the right, and select "Serial," "Network" or
"NoAsign".
"Serial" can be selected only with Group 1.
After the method has been changed, click the [SET] button to
reflect the change.
 CAMERA Name
The names of the cameras set in the remote cameras are
displayed in this column.
They are displayed for the remote cameras in the
currently selected group.
For remote cameras with a serial connection, they are
displayed only when the cameras are selected by the unit.
 SW Input
The input connectors of the switcher are displayed in this
column.
The input connector can be changed manually.
Click
on the right, and select "NoAsign" or an input
connector from "INPUT1" to "INPUT5."
After the connector has been changed, click the [SET] button
to reflect the change.
 MAC Address
The MAC addresses of the remote cameras and switcher
connected to the selected AW-RP50 are displayed in this
column.
 IP Address
The IP addresses of the remote cameras and switcher
connected to the selected AW-RP50 are displayed in this
column.
The IP addresses can be changed by inputting them directly.
After inputting an IP address, click the [SET] button to reflect
the change.
 HTTP Port
The numbers of the ports used to connect the selected
AW-RP50 are displayed in this column.
 CAMERA Select
The numbers of the cameras to be changed are displayed
in this column.
The numbers of the cameras can be changed manually.
Click
on the right, and select a number from "C001" to
"C100."
After the camera number has been changed, click the [SET]
button to reflect the change.
 Alarm
The alarm information of the remote cameras is displayed
in this column.
They are displayed for the remote cameras in the
currently selected group.
For remote cameras with a serial connection, they are
displayed only when the cameras are selected.
38 (E)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis